Cooling system
Drain the cooling circuit completely.
- Unscrew the and remove the five wa-
ter pomp cover fastening screws.
- Loosen the clip and remove the cover.
REMOVING THE PUMP ROTOR
Remove the H2O pump cover.
Unscrew the rotor and remove it, not-
ing the left hand thread on the pin.