Installing A Tpm Or Tcm - Huawei RH8100 V3 User Manual

Table of Contents

Advertisement

RH8100 V3 Server
User Guide
Step 3 Remove the TPM from the HFC. See step (2) in
Step 4 Place the removed TPM in an ESD bag.
----End

5.10.4 Installing a TPM or TCM

This topic describes how to install a trusted platform module (TPM) or trusted
cryptography module (TCM).
Scenarios
Install a TPM or TCM if:
Prerequisites
Conditions
Data
Tools
Hardware
Spare TPM
Procedure
Step 1 Wear an ESD wrist strap or ESD gloves. For details, see
Step 2 Take the spare TPM out of its ESD bag.
Issue 30 (2019-12-19)
A TPM or TCM has failed.
A TPM or TCM needs to be replaced with a new model.
A TPM and a TCM are similar in terms of appearance and replacement procedure. This topic
describes how to install a TPM.
You have powered off the RH8100 V3. For details, see
RH8100
V3. Then you have removed all power cables from the server.
You have removed the High-performance Fusion Console (HFC) from the
RH8100 V3. For details, see
You have obtained the cabinet number and chassis number of the RH8100 V3.
You have located the RH8100 V3 based on the preceding information, and
labeled its panel to prevent misoperations.
You have determined the position on the RH8100 V3 for installing a TPM.
ESD gloves
M3 Phillips screwdriver
Packaging materials, for example, an ESD bag
Copyright © Huawei Technologies Co., Ltd.
5 Removing and Installing Parts of the RH8100 V3
Figure
5.10.1 Removing an
5-141.
6.2 Powering Off the
HFC.
1 Safety
Instructions.
268

Advertisement

Table of Contents
loading

Table of Contents