Remove a PCIe card if it has failed.
Prerequisites
Conditions
Data
Tools
Procedure
Step 1 Wear an ESD wrist strap or ESD gloves. For details, see
Step 2 (Optional) If the RH8100 V3 is configured with a GPU, remove the power cables
between the front I/O module and the GPU, as shown in
Figure 5-43 GPU power cables
Issue 30 (2019-12-19)
You have powered off the RH8100 V3. For details, see
RH8100
V3. Then you have removed all power cables from the server.
You have removed the front I/O module from the RH8100 V3. For details, see
5.5.1 Removing the Front I/O
You have removed the riser card from the RH8100 V3. For details, see
Removing a Riser
Card.
You have obtained the cabinet number and chassis number of the RH8100 V3.
You have located the RH8100 V3 based on the preceding information, and
labeled its panel to prevent misoperations.
You have determined the position on the RH8100 V3 for removing a PCIe
card.
ESD gloves
Packaging materials, for example, an ESD bag
Copyright © Huawei Technologies Co., Ltd.