Huawei RH8100 V3 User Manual page 89

Table of Contents

Advertisement

RH8100 V3 Server
User Guide
Category
Power
specifications
Power
consumption
specifications
Note: For more accurate specifications, use
Issue 30 (2019-12-19)
Item
PSU power
rating
Power
consumption
for 4–socket
server
Power
consumption
for 4–socket
server
Copyright © Huawei Technologies Co., Ltd.
Specifications
The RH8100 V3 supports PSUs in 2+2 or 1+1
redundancy mode. The following lists the
power rating for each type of PSU:
● 2500 W DC PSU: 2500 W (input voltage: –
48 V DC to –60 V DC)
● 2000 W AC PSU:
– 800 W (90-143 V AC input)
– 1800 W (180-242 V AC input)
– 2000 W (198-264 V AC input)
– 2000 W (216-264 V DC input)
● 3000 W AC PSU:
– 1200 W (90-143 V AC input)
– 2500 W (180-242 V AC input)
– 3000 W (200-264 V AC input)
– 3000 W (216-264 V DC input)
● Maximum power consumption: 1313.94 W
● Typical power consumption: 1041.54 W
● Minimum power consumption: 769.73 W
● Maximum power consumption: 2627.88 W
● Typical power consumption: 2083.07 W
● Minimum power consumption: 1539.46 W