5.5.6 Installing a Riser Card

This topic describes how to install a riser card.
Scenarios
Install a riser card if:
Prerequisites
Conditions
Data
Tools
Hardware
Spare riser card
Procedure
Step 1 Wear an ESD wrist strap or ESD gloves. For details, see
Step 2 Take the spare riser card out of the ESD bag, and install all PCIe cards of the
required model on the riser card.
Step 3 Insert the riser card into the slot on the front I/O module. See step (1) in
5-41.
Step 4 Press the ejector lever as far as it will go. See step (2) in
Step 5 Tighten the screws on the riser card. See step (3) in
Issue 30 (2019-12-19)
A riser card has failed.
A PCIe card on the riser card has failed.
You have powered off the RH8100 V3. For details, see
RH8100
V3. Then you have removed all power cables from the server.
You have removed the front I/O module from the RH8100 V3. For details, see
5.5.1 Removing the Front I/O
You have installed all PCIe cards on the riser card. For details, see
Installing a PCIe
Card.
You have obtained the cabinet number and chassis number of the RH8100 V3.
You have located the RH8100 V3 based on the preceding information, and
labeled its panel to prevent misoperations.
You have determined the position on the RH8100 V3 for installing a riser card.
ESD gloves
Packaging materials, for example, an ESD bag
M3 Phillips screwdriver