  • Page 1 Tecal RH5485 Server V100R001C00 Installation and User’s Guide Issue Date 2011-05-25 HUAWEI TECHNOLOGIES CO., LTD.
  • Page 3: Issue

    Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS"...
  • Page 5: About This Document

    Indicates a tip that may help you solve a problem or save time. Provides additional information to emphasize or supplement important points of the main text. Issue 02 (2011-05-25) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd...
  • Page 6: Change History

    This issue is the second official release, which incorporates the following changes: Some figures in chapter 2 are updated. Some format errors are modified. Changes in Issue 01 (2010-08-30) Initial field trial release. Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 7: Table Of Contents

    Installation and User’s Guide Contents Contents About This Document ........................iii 1 The Tecal RH5485 server ......................1-1 1.1 The HUAWEI Documentation CD ........................ 1-1 1.1.1 Hardware and software requirements ....................1-1 1.1.2 Using the Documentation Browser ...................... 1-1 1.2 Related documentation ..........................1-2 1.3 Notices and statements in this document.......................
  • Page 8 4.3.3 Recognized ............................4-2 4.4 RoHS ................................4-2 5 How to Obtain Help ........................5-1 5.1 Preparations Before Contacting Huawei ....................... 5-1 5.1.1 Collecting Problem Information ......................5-1 5.1.2 Making Debugging Preparations......................5-1 5.2 How to Use the Document ..........................5-1 5.3 How to Obtain Help From Website .......................
  • Page 9 Figure 2-17 Push the adapter retention latch ....................2-21 Figure 2-18 Push the adapter retention latch ....................2-23 Figure 2-19 Route the SAS cables ........................2-24 Figure 2-20 Install a hot-swap power supply ....................2-26 Issue 02 (2011-05-25) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd...
  • Page 10 Figure 2-41 Position the microprocessor with the microprocessor tool ............2-48 Figure 2-42 Secure the microprocessor ......................2-48 Figure 2-43 Locations of the input and output connectors ................2-50 viii Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 11 Table 2-2 Low-cost and low-power DIMM installation sequence ..............2-37 Table 2-3 Low-cost and low-power memory-card installation sequence ............2-37 Table 2-4 High-performance memory-card installation sequence ..............2-37 Issue 02 (2011-05-25) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd...
  • Page 13: The Tecal Rh5485 Server

    Problem Determination and Service Guide that is on the HUAWEI Documentation CD. The HUAWEI Tecal RH5485 server is a 4U1-high, high-performance server. It can be upgraded to a symmetric multiprocessing (SMP) server through a microprocessor upgrade. It...
  • Page 14: Related Documentation

    Safety Information document.  Problem Determination and Service Guide This document is in PDF on the HUAWEI Documentation CD. It contains information to help you solve problems yourself, and it contains information for service technicians. ...
  • Page 15: Notices And Statements In This Document

    Tecal RH5485 Server Installation and User’s Guide 1 The Tecal RH5485 server Depending on the server model, additional documentation might be included on the HUAWEI Documentation CD. 1.3 Notices and statements in this document The caution and danger statements in this document are also in the multilingual Safety Information document, which is on the HUAWEI Documentation CD.
  • Page 16: What Your Server Offers

    Tecal RH5485 Server 1 The Tecal RH5485 server Installation and User’s Guide Table 1-1 Features and specifications 1.5 What your server offers The server uses the following features and technologies: Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 17 Web browser (For more information, see “Using the integrated management module”.)  X-Architecture® technology X-Architecture technology combines proven, innovative HUAWEI designs to make your x86-processor-based server powerful, scalable, and reliable.  Large system-memory capacity The server supports up to 1 TB of system memory. The memory controller supports error...
  • Page 18: Reliability, Availability, And Serviceability

    Tecal RH5485 Server 1 The Tecal RH5485 server Installation and User’s Guide  Integrated Trusted Platform Module (TPM) This integrated security chip performs cryptographic functions and stores private and public secure keys. It provides the hardware support for the Trusted Computing Group (TCG) specification.
  • Page 19 Tecal RH5485 Server Installation and User’s Guide 1 The Tecal RH5485 server − Full array memory mirroring (FAMM) redundancy − Automatic failover recovery for UEs when FAMM is configured − Automated logical removal of failed DIMMs on reboots prior to replacement −...
  • Page 20: The Updatexpress System Pack Installer (Uxspi)

    Tecal RH5485 Server 1 The Tecal RH5485 server Installation and User’s Guide 1.7 The UpdateXpress System Pack Installer (UXSPI) The UpdateXpress System Pack Installer detects supported and installed device drivers and firmware in the server and installs available updates. 1.8 Server controls, LEDs, and power This section describes the controls, light-emitting diodes (LEDs), connectors on the front and rear of the server, and how to turn the server on and off.
  • Page 21: Figure 1-2 Operator Information Panel

    LED. When this LED is lit, it indicates that the drive has failed. If an optional HUAWEI ServeRAID controller is installed in the server, when this LED is flashing slowly (one flash per second), it indicates that the drive is being rebuilt. When the LED is flashing rapidly (three flashes per second), it indicates that the controller is identifying the drive.
  • Page 22: Figure 1-3 Light Path Diagnostics Panel

    Tecal RH5485 Server 1 The Tecal RH5485 server Installation and User’s Guide In a two-node configuration, this LED is lit on the primary server and flashes on the secondary server during POST. You can press this button or use an IPMI command to turn this LED on or off.
  • Page 23: Rear View

     NMI button: Press this button to force a nonmaskable interrupt to the microprocessor, if you are directed to do so by HUAWEI service.  Reset button: Press this button to reset the server and run the power-on self-test (POST).
  • Page 24: Rear View Leds

    Tecal RH5485 Server 1 The Tecal RH5485 server Installation and User’s Guide Power-cord connector: Connect the power cord to this connector. System-management connector: Use this connector to connect the server to a network for systems-management information control. This connector is used only by the IMM.
  • Page 25: Figure 1-6 Rear View Leds

    Tecal RH5485 Server Installation and User’s Guide 1 The Tecal RH5485 server Figure 1-6 Rear view LEDs AC power LED: Each hot-swap power supply has an ac power LED and a dc power LED. When the ac power LED is lit, it indicates that sufficient power is coming into the power supply through the power cord.
  • Page 26: Server Power Features

    Tecal RH5485 Server 1 The Tecal RH5485 server Installation and User’s Guide System-error LED: When this LED is lit, it indicates that a system error has occurred. An LED on the light path diagnostics panel is also lit to help isolate the error.
  • Page 27 Tecal RH5485 Server Installation and User’s Guide 1 The Tecal RH5485 server Statement 5: CAUTION The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord.
  • Page 29: Installing Optional Devices

    If the server is not working correctly, see the Problem Determination and Service Guide on the HUAWEI Documentation CD for information about how to run diagnostics. This chapter provides detailed instructions for installing optional hardware devices in the server.
  • Page 30: Figure 2-1 Server Components

    (Orange can also indicate touch points on hot-swap components.) See the instructions for Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 31: Figure 2-2 Memory-Card Dimm Connectors

    The following illustration shows the DIMM connectors on a memory card. Figure 2-2 Memory-card DIMM connectors Memory-card LEDs The following illustration shows the LEDs on a memory card. Issue 02 (2011-05-25) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd...
  • Page 32: Figure 2-3 Memory-Card Leds

    2 Installing optional devices Installation and User’s Guide Figure 2-3 Memory-card LEDs SAS-backplane connectors The following illustration shows the hard disk drive connectors on the SAS backplane. Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 33: Figure 2-4 Sas-Backplane Connectors

    The following illustration shows the cable connectors on the eXFlash backplane. Figure 2-5 eXFlash backplane connectors Microprocessor-board connectors The following illustration shows the connectors on the microprocessor board. Issue 02 (2011-05-25) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd...
  • Page 34: Figure 2-6 Microprocessor-Board Connectors

    Tecal RH5485 Server 2 Installing optional devices Installation and User’s Guide Figure 2-6 Microprocessor-board connectors Microprocessor-board LEDs The following illustration shows the LEDs on the microprocessor board. Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 35: Figure 2-7 Microprocessor-Board Leds

    Tecal RH5485 Server Installation and User’s Guide 2 Installing optional devices Figure 2-7 Microprocessor-board LEDs I/O-board connectors The following illustration shows the connectors on the I/O board. Issue 02 (2011-05-25) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd...
  • Page 36: Figure 2-8 I/O-Board Connectors

    Tecal RH5485 Server 2 Installing optional devices Installation and User’s Guide Figure 2-8 I/O-board connectors I/O-board jumpers The following illustration shows the jumpers on the I/O board. Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 37: Figure 2-9 I/O-Board Jumpers

    If no jumper is present, the server responds as if the jumper is on pins 1 and 2. I/O-board LEDs The following illustration shows the LEDs on the I/O board. Issue 02 (2011-05-25) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd...
  • Page 38: Installation Guidelines

    To download firmware updates for your server, complete the following steps. NOTE Changes are made periodically to the HUAWEI Web site. The actual procedure might vary slightly from what is described in this document. In a two-node configuration, make sure that the Server Firmware, FPGA, and IMM code are at the same levels on all nodes.
  • Page 39: System Reliability Guidelines

    Do not place objects in front of the fans. For proper cooling and airflow, replace the top cover before you turn on the server. Operating the server for extended Issue 02 (2011-05-25) Huawei Proprietary and Confidential 2-11 Copyright © Huawei Technologies Co., Ltd...
  • Page 40: Working Inside The Server With The Power On

    To reduce the possibility of damage from electrostatic discharge, observe the following precautions:  Limit your movement. Movement can cause static electricity to build up around you. 2-12 Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 41: Internal Cable Routing And Connectors

    2.3 Internal cable routing and connectors The following illustration shows the routing of the DVD power, fans 1 and 2, scalability LED, and operator information cables. Issue 02 (2011-05-25) Huawei Proprietary and Confidential 2-13 Copyright © Huawei Technologies Co., Ltd...
  • Page 42: Figure 2-11 Routing Of The Dvd Power, Fans 1 And 2, Scalability Led, And Operator Information Cables

    Figure 2-11 Routing of the DVD power, fans 1 and 2, scalability LED, and operator information cables The following illustration shows the routing of the USB and DVD signal cables. 2-14 Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 43: Figure 2-12 Routing Of The Usb And Dvd Signal Cables

    Tecal RH5485 Server Installation and User’s Guide 2 Installing optional devices Figure 2-12 Routing of the USB and DVD signal cables Issue 02 (2011-05-25) Huawei Proprietary and Confidential 2-15 Copyright © Huawei Technologies Co., Ltd...
  • Page 44: Removing The Top Cover

    19990305 error code is displayed, indicating that an operating system was not found but the server is otherwise working correctly. If the server is not working correctly, see the Problem Determination and Service Guide on the HUAWEI Documentation CD for information about how to run diagnostics. To remove the top cover, complete the following steps: 1.
  • Page 45: Removing The Top-Cover Bracket

    2.5 Removing the top-cover bracket To remove the top-cover bracket, complete the following steps: 1. Read t h e Tecal RH5485 Safety Information. 2. If you are installing or replacing a non-hot-swap component, turn off the server and all peripheral devices, and disconnect the power cords and all external cables.
  • Page 46: Installing The Top-Cover Bracket

    3. Slide the blue latches on the top cover bracket toward the outside of the server to lock it in place. 2-18 Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 47: Removing The Bezel

    You do not have to remove the top cover before you remove the bezel. To remove the bezel, complete the following steps: 1. Read t h e Tecal RH5485 Safety Information 2. Press on the bezel retention tabs on the sides of the bezel and pull the bezel away from the server.
  • Page 48 To install a PCI Express adapter, complete the following steps. 1. Read t h e Tecal RH5485 Safety Information. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables.
  • Page 49: Figure 2-17 Push The Adapter Retention Latch

    11. Connect any required cables to the adapter. If you have other devices to install or remove, do so now. Otherwise, go to“Completing the installation”. Issue 02 (2011-05-25) Huawei Proprietary and Confidential 2-21 Copyright © Huawei Technologies Co., Ltd...
  • Page 50: Installing A Serveraid Adapter For Use With Exflash Drives

    To install a ServeRAID adapter, for use with eXFlash drives, in a rear PCI connector, complete the following steps. 1. Read t h e Tecal RH5485 Safety Information. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables.
  • Page 51: Figure 2-18 Push The Adapter Retention Latch

    10. Push down on the blue adapter retention latch until it clicks into place, securing the adapter. 11. Route the SAS cables under the bottom of the I/O shuttle. Issue 02 (2011-05-25) Huawei Proprietary and Confidential 2-23 Copyright © Huawei Technologies Co., Ltd...
  • Page 52: Figure 2-19 Route The Sas Cables

    Connect one end of the second cable to Port 1 on the ServeRAID adapter and the other end to connector J40 on the backplane. 13. Reinstall the top cover bracket. 2-24 Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 53: Installing A Hot-Swap Power Supply

    The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source. Issue 02 (2011-05-25) Huawei Proprietary and Confidential 2-25 Copyright © Huawei Technologies Co., Ltd...
  • Page 54: Installing A Hot-Swap Hard Disk Drive

    Figure 2-20 Install a hot-swap power supply To install an additional hot-swap power supply, complete the following steps: 1. Read t h e Tecal RH5485 Safety Information . 2. Press the blue release latch on the power-supply filler and pull the handle to the open position.
  • Page 55: Figure 2-21 Install A Hot-Swap Hard Disk Drive

    Figure 2-21 Install a hot-swap hard disk drive To install a hot-swap hard disk drive, complete the following steps: 1. Read t h e Tecal RH5485 Safety Information. 2. Remove the filler panel from one of the empty hot-swap bays.
  • Page 56: Installing A Dvd (Optical) Drive

    Figure 2-22 Install a DVD drive To install a DVD drive, compete the following steps: 1. Read t h e Tecal RH5485 Safety Information. 2. Turn off the server and peripheral devices, and disconnect the power cord and all external cables.
  • Page 57: Installing A 2.5-Inch Hard Disk Drive Backplane

    2.13 Installing a 2.5-inch hard disk drive backplane To install a 2.5-inch hard disk drive backplane, complete the following steps: 1. Read t h e Tecal RH5485 Safety Information. 2. Turn off the server and peripheral devices, and disconnect the power cord and all external cables.
  • Page 58: Figure 2-23 Remove The Backplane Carrier And Sas Power Cable Handle

    Figure 2-23 Remove the backplane carrier and SAS power cable handle 11. Remove the backplane filler from the backplane carrier. Figure 2-24 Remove the backplane filler a. Push the tabs on the backplane outward. 2-30 Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 59: Figure 2-25 Orient And Install The New Backplane

    0 and the cable from the new top backplane to port 1. The following graphics show the port numbers on the ServeRAID adapters. Issue 02 (2011-05-25) Huawei Proprietary and Confidential 2-31 Copyright © Huawei Technologies Co., Ltd...
  • Page 60: Figure 2-26 Serveraid M5015 Controller

    18. Install the ServeRAID adapter onto the RAID adapter carrier, and then install the carrier into the server. Figure 2-28 Install the ServeRAID adapter onto the RAID adapter carrier 2-32 Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 61: Installing A Qpi Wrap Card

    QPI wrap cards in the server. To install a QPI wrap card, complete the following steps: 1. Read t h e Tecal RH5485 Safety Information. 2. Turn off the server and peripheral devices, and disconnect the power cord and all external cables.
  • Page 62: Installing An Internal Removable Flash Drive

    Figure 2-30 Install an internal removable flash drive To install an internal removable flash drive, complete the following steps: 1. Read t h e Tecal RH5485 Safety Information. 2. Disconnect the power cable and remove the power supply that is closest to theUSB connector that you plan to use.
  • Page 63: Memory Modules

    1, 4, 2, and 3. See “Installing a microprocessor” on page 67 for more information.) The following illustration shows the locations of the memory-card connectors. Issue 02 (2011-05-25) Huawei Proprietary and Confidential 2-35 Copyright © Huawei Technologies Co., Ltd...
  • Page 64: Figure 2-31 Locations Of The Memory-Card Connectors

    Figure 2-31 Locations of the memory-card connectors  The following illustration shows the DIMM connectors on a memory card. Figure 2-32 DIMM connectors on a memory card 2-36 Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 65: Table 2-2 Low-Cost And Low-Power Dimm Installation Sequence

    DIMM pair Memory-card DIMM connector installation order connector number numbers First 1 and 8 Second 1 and 8 Third 1 and 8 Fourth 1 and 8 Issue 02 (2011-05-25) Huawei Proprietary and Confidential 2-37 Copyright © Huawei Technologies Co., Ltd...
  • Page 66 7 and 8 mirror each other. Install DIMMs in the sequence shown in the following table. Table 7. Memory-card installation sequence for memory-mirroring configuration DIMM quad Memory card Connector numbers installation order First 1 and 8 1 and 8 2-38 Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 67 DIMM. When this occurs, first identify the defective DIMM; then, remove and replace the DIMM. The following illustration shows the LEDs on the memory card. Issue 02 (2011-05-25) Huawei Proprietary and Confidential 2-39 Copyright © Huawei Technologies Co., Ltd...
  • Page 68: Figure 2-33 Leds On The Memory Card

    At least one memory card with one pair of DIMMs must be installed for the server to operate correctly. To install a memory card, complete the following steps: 1. Read t h e Tecal RH5485 Safety Information. 2-40 Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright ©...
  • Page 69: Installing Dimms

    3 though 7 for each memory card. To install a DIMM, complete the following steps: 1. Read t h e Tecal RH5485 Safety Information. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables as necessary to replace the device.
  • Page 70: Figure 2-34 Remove The Server Top Cover

    To avoid breaking the DIMM retaining clips or damaging the DIMM connectors, open and close the clips gently. 6. Open the retaining clips 1 on each end of the DIMM connector. 2-42 Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 71: Figure 2-35 Insert The Dimm Into The Connector

    If there is a gap between the DIMM and the retaining clips, the DIMM has not been correctly inserted; open the retaining clips, remove the DIMM, and then reinsert it. 10. Install the memory card. Issue 02 (2011-05-25) Huawei Proprietary and Confidential 2-43 Copyright © Huawei Technologies Co., Ltd...
  • Page 72: Installing A Microprocessor

     The optional microprocessors that HUAWEI supports are limited by the capacity and capability of the server. Any microprocessors that you install must have the same specifications as the microprocessors that came with the server.
  • Page 73: Figure 2-37 Populate The Microprocessor Sockets

    To install a microprocessor, complete the following steps: 1. Read t h e Tecal RH5485 Safety Information. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables as necessary to replace the device.
  • Page 74: Figure 2-38 Slide The Blue Latches

    5. Lift the top cover bracket out of the server. 6. Remove the heat-sink blank and store it for future use. 7. Open the release socket lever and rotate the load plate. 2-46 Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 75: Figure 2-39 Open The Release Socket Lever

    Twist the handle of the installation tool clockwise to secure the microprocessor in the tool. NOTE You can pick up or release the microprocessor by twisting the microprocessor installation tool handle. Figure 2-40 Pick up the microprocessor Issue 02 (2011-05-25) Huawei Proprietary and Confidential 2-47 Copyright © Huawei Technologies Co., Ltd...
  • Page 76: Figure 2-41 Position The Microprocessor With The Microprocessor Tool

    Figure 2-41 Position the microprocessor with the microprocessor tool 11. Close the load plate and then rotate the microprocessor-release lever to secure the microprocessor. Figure 2-42 Secure the microprocessor 2-48 Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 77: Completing The Installation

    The following illustration shows the locations of the input and output connectors on the rear of the server. Issue 02 (2011-05-25) Huawei Proprietary and Confidential 2-49 Copyright © Huawei Technologies Co., Ltd...
  • Page 78: Figure 2-43 Locations Of The Input And Output Connectors

    RAID adapter for information about reconfiguring the disk arrays. For information about configuring the integrated Gigabit Ethernet controller, see “Configuring the Broadcom Gigabit Ethernet controller”. 2-50 Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 79: Configuring The Server

    Use the integrated management module (IMM) for configuration, to update the firmware and sensor data record/field replaceable unit (SDR/FRU) data, and to remotely manage a network. For information about using the IMM, see “Using the integrated management module” and the Integrated Management Module User's Guide on the HUAWEI Web site. ...
  • Page 80: Using The Setup Utility

    Setup utility, some of those changes are reflected in the system information; you cannot change settings directly in the system information. This choice is on the full Setup utility menu only. Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 81 Select this choice to maintain the optimal balance between performance and power consumption. The server generally produces the best performance per watt while it is in this mode. Issue 02 (2011-05-25) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd...
  • Page 82 The default is Disable. - Legacy Thunk Support Select this choice to enable or disable UEFI to interact with PCI mass storage devices that are not UEFI compliant. Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 83 This choice is on the full and limited Setup utility menu. − Set Power-on Password Select this choice to set or change a power-on password. For more information, see “Power-on password” on. Issue 02 (2011-05-25) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd...
  • Page 84: Password

    You can use any combination of up to seven characters (A - Z, a - z, and 0 - 9) for the password. Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 85: Administrator Password

    Start the Setup utility and reset the power-on password.  Remove the battery from the server and then reinstall it. For instructions for removing the battery, see the Problem Determination and Service Guide on the HUAWEI Documentation CD. CAUTION Before you change any switch settings or move any jumpers, turn off the server;...
  • Page 86: Using The Boot Selection Menu Program

    The ServerGuide program simplifies operating-system installations by providing updated device drivers and, in some cases, installing them automatically. The ServerGuide program requires a supported HUAWEI server with an enabled startable (bootable) CD drive. In addition to the ServerGuide Setup and Installation CD, you must have your operating-system CD to install the operating system.
  • Page 87: Serverguide Features

    When you use the ServerGuide Setup and Installation CD, you do not need setup diskettes. You can use the CD to configure any supported HUAWEI server model. The setup program provides a list of tasks that are required to set up your server model. On a server with a ServeRAID adapter or integrated SCSI controller with RAID capabilities, you can run the SCSI RAID configuration program to create logical drives.
  • Page 88: Using The Integrated Management Module

    If you have already configured the server hardware and you are not using the ServerGuide program to install your operating system, download the latest operating-system installation instructions from the HUAWEI Web site. 3.5 Using the integrated management module The integrated management module (IMM) is a second generation of the functions that were formerly provided by the baseboard management controller hardware.
  • Page 89: Obtaining The Ip Address For The Web Interface Access

    Setup utility menu. 3. Select System S ettings → Integrated Management Module → Network Configuration. 4. Locate the IP address. 5. Exit from the Setup utility. Issue 02 (2011-05-25) Huawei Proprietary and Confidential 3-11 Copyright © Huawei Technologies Co., Ltd...
  • Page 90: Logging On To The Web Interface

    IMM detects an operating-system hang condition. A system administrator can use the blue-screen capture to assist in determining the cause of the hang condition. 3-12 Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 91: Enabling The Broadcom Gigabit Ethernet Utility Program

    4. Press Enter to refresh the list of device drivers. 5. Select the device driver for your RAID controller and press Enter. 6. Follow the instructions in the documentation for your RAID controllers. Issue 02 (2011-05-25) Huawei Proprietary and Confidential 3-13 Copyright © Huawei Technologies Co., Ltd...
  • Page 93: Regulatory Compliance Standards

    UL has its own certification system for the whole product, components, and materials. All the electric products that are exported to the USA must pass the UL certification. Issue 02 (2011-05-25) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd...
  • Page 94: Listed

    The product passes the RoHS certification and the contents of hazardous substances in the product comply with SJ/T-11363-2006 Requirements for concentration limits for certain hazardous substances in electronic information products. Huawei Proprietary and Confidential Issue 02 (2011-05-25) Copyright © Huawei Technologies Co., Ltd...
  • Page 95: How To Obtain Help

    Problem level and required solution deadline 5.1.2 Making Debugging Preparations When you seek for technical support, Huawei technical engineer may help you to perform some operations to further collect the fault information or remove the fault. Therefore, you need to make preparations before seeking for technical support.
  • Page 96: How To Obtain Help From Website

    5 How to Obtain Help Installation and User’s Guide 5.3 How to Obtain Help From Website Huawei provides users with timely and efficient technical support through the regional offices, secondary technical support system, telephone technical support, remote technical support, and onsite technical support.

Table of Contents