General Data - Siemens SINAMICS G150 Operating Instructions Manual

Converter cabinet units 1750 kw 2700 kw
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

Technical specifications

12.2 General data

12.2
General data
Table 12- 1
General technical data
Electrical data
Line system configurations
Line frequency
Output frequency
Power factor
- Fundamental mode
- Total
Converter efficiency
Switching at input
Overvoltage category
Mechanical data
Degree of protection
Class of protection
Cooling method
Sound pressure level L
pA
Touch protection
Cabinet system
Paint finish
Compliance with standards
Standards
CE mark
RI suppression
Ambient conditions
Ambient temperature
Humidity range
2)
(non-condensing)
corresponds to class
Environmental class/harmful
chemical substances
2)
Organic/biological influences
Degree of pollution
Installation altitude
646
Grounded TN/TT systems or ungrounded IT systems (a grounded phase conductor is not
permissible in 690 V line supplies)
47 ... 63 Hz
0 ... 300 Hz
≥ 0.96
0.75 ... 0.93
> 98%
Once every 3 minutes
III per EN 61800-5-1
IP20 (higher degrees of protection up to IP54 optional)
I per EN 61800-5-1
Forced air cooling AF according to EN 60146
(1 m)
At 50 Hz line frequency: ≤ 75 dB(A) (synchronizers)
At 60 Hz line frequency: ≤ 78 dB(A) (synchronizers)
EN 50274 and BGV A3 when used as intended
Rittal TS 8, doors with double-barb lock, three-section base plates for cable entry
RAL 7035 (indoor requirements)
EN 60146-1, EN 61800-2, EN 61800-3, EN 61800-5-1, EN 60204-1, EN 60529
In accordance with EMC Directive No. 2014/30/EU and Low-Voltage Directive
No. 2014/35/EU and Machinery Directive No. 2006/42/EC
In accordance with the EMC product standard for variable-speed drives EN 61800-3, "sec-
ond environment".
Application in "first environment" possible with line filters (option L00)
Storage
-25 ... +55 °C
5 to 95%
1K4 to EN 60721-3-1
1C2 to EN 60721-3-1
1B1 to EN 60721-3-1
2)
2 according to EN 61800-5-1
Up to 2000 m above sea level without derating,
> 2000 m above sea level with derating (see "Derating data")
Transport
-25 ... +70 °C
–40 °C
from
for 24 hours
5 ... 95% at 40° C
2K3 to EN 60721-3-2
2C2 to EN 60721-3-2
2B1 to EN 60721-3-2
Operating Instructions, 07/2016, A5E03347396A
2)
.
1)
Operation
0
... +40 °C
up to 50 °C with derating
95%
5 ...
3K3 to EN 60721-3-3
3C2 to EN 60721-3-3
3B1 to EN 60721-3-3
Converter cabinet units

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents