Siemens SINAMICS G150 Operating Instructions Manual page 300

Converter cabinet units 1750 kw 2700 kw
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

Operation
6.6 Control via the operator panel
Normalization for VECTOR object
Table 6- 6
Normalization for VECTOR object
Size
Reference speed
Reference voltage
Reference current
Reference torque
Reference power
Reference frequency
Reference modulation
depth
Reference flux
Reference temperature
Object B_INF
Table 6- 7
List of signals for the operation screen - object B_INF
Signal
DC link voltage smoothed
Temperature of power unit
Normalization for object B_INF
Table 6- 8
Normalization for object B_INF
Variable
Reference voltage
Reference temperature
300
Scaling parameter
100% = p2000
100% = p2001
100% = p2002
100% = p2003
100% = r2004
100% = p2000/60
100 % = Maximum output voltage without overload
100 % = Rated motor flux
100% = p2006
Factory setting (entry no.)
(1)
(2)
Normalization parameters
100% = p2001
100% = p2006
Default for quick commissioning
p2000 = Maximum speed (p1082)
p2001 = 1000 V
p2002 = Current limit (p0640)
p2003 = 2 x rated motor torque
r2004 = (p2003 x p2000 x π) / 30
p2006 = 100°C
Parameter
Short name
r0026
U_DC
r0037
T_LT
Default for quick commissioning
p2001 = r0206/r0207
p2006 = 100°C
Operating Instructions, 07/2016, A5E03347396A
Unit
Scaling (100 %=...) See
table below
V
p2001
°C
p2006