Synchronization interval
The interval for time synchronization is set from 1 hour (factory setting) to 99 hours.
For the interval, the time in the AOP from the time of the last change of the interval is
decisive.
Daylight saving (factory setting: No)
● No
The time does not automatically change over to daylight-saving time.
● Yes
Selection is only possible if synchronization is set to "None" or "AOP -> Drive".
The time is then automatically set to summer or winter time.
After the changeover - for synchronization "AOP -> Drive" - synchronization is
immediately carried out, irrespective of the synchronization interval set.
Changes to the synchronization must be saved with "Save".
Date format
In this menu, the date format can be set:
● DD.MM.YYYY: European date format
● MM/DD/YYYY: North American date format
DO name display mode
In this menu, you can switch the display of the DO name between the standard abbreviation
(e.g. VECTOR) and a user-defined DO name (e.g. Motor_1).
User-defined DO name (factory setting: No)
● Yes: The "User-defined DO name" stored in parameter p0199 is displayed, instead of the
standard DO abbreviation.
● No: The standard DO abbreviation is displayed.
Converter cabinet units
Operating Instructions, 07/2016, A5E03347396A
6.6 Control via the operator panel
Operation
303