Technical Data; Technical Data Of The G115D Wall-Mounted Converter; General Converter Technical Data - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive for conveyor applications
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Technical data

11.1

Technical data of the G115D wall-mounted converter

11.1.1

General converter technical data

Electrical data
Property
Line voltage
Line supply configurations
Output voltage
Line frequency
Output frequency
Converter efficiency
Power factor λ
cos φ
Line impedance
Inrush current
Overvoltage category
Pulse frequency
Maximum short-circuit current (SCCR
or Icc)
Minimum short-circuit current
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA
Explanation
For systems according to IEC:
– 3 AC 380 V (-10 %) ... 480 V (+10 %)
For systems according to UL:
– 3 AC 380Y/220 V ... 480Y/277 V
The actual permissible line voltage depends upon the installation altitude.
TN, TT, IT
1)
Not for corner-grounded network.
Permissible line supplies (Page 52)
3 AC 0 V ... line voltage
50 Hz/60 Hz (±10%)
0 Hz ... 550 Hz in U/f
0 Hz ... 240 Hz in SLVC
96% ... 98%
0.80 ... 0.91
0.98 ... 0.99
Uk<4% (RSC>25)
Less than 2 × rated input current.
The converter can withstand 100000 power cycles with an interval of 120 s.
III, according to IEC 61800-5-1
4 kHz (default); 4 kHz...16 kHz (in steps of 2 kHz)
Current derating as a function of the pulse frequency (Page 420)
When using fuses: 65 kA rms
You can find the data for further overcurrent protection devices on the Internet:
Branch protection and short-circuit strength according to UL and IEC
support.industry.siemens.com/cs/ww/en/ps/27867)
5 kA rms
11
(https://
411

Advertisement

Table of Contents
loading

Table of Contents