Stop Method For Lsp (Forward Rotation Stroke End) Off Or Lsn (Reverse Rotation Stroke End) Off - Mitsubishi Electric MELSERVO-J4 Series Instruction Manual

General-purpose interface ac servo. servo amplifier
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

7. PARAMETERS

7.5 Stop method for LSP (Forward rotation stroke end) off or LSN (Reverse rotation stroke end) off

Select a servo motor stop method for when LSP (Forward rotation stroke end) or LSN (Reverse rotation stroke
end) is off with the first digit of [Pr. PD30].
[Pr. PD30]
setting
During rotation at constant speed
_ _ _ 0
No S-pattern acceleration/
deceleration
(initial
With S-pattern acceleration/
value)
deceleration
Servo motor speed
(linear servo motor
speed)
0 r/min
(0 mm/s)
LSP
or
LSN
_ _ _ 1
No S-pattern acceleration/
deceleration
With S-pattern acceleration/
deceleration
Servo motor speed
(linear servo motor
speed)
0 r/min
(0 mm/s)
LSP
or
LSN
_ _ _ 2
No S-pattern acceleration/
deceleration
(Note 1)
With S-pattern acceleration/
deceleration
Servo motor speed
(linear servo motor
speed)
0 r/min
(0 mm/s)
LSP
ON
or
OFF
LSN
_ _ _ 3
No S-pattern acceleration/
deceleration
(Note 2)
With S-pattern acceleration/
deceleration
Servo motor speed
(linear servo motor
speed)
0 r/min
(0 mm/s)
LSP
or
LSN
Note 1. This will be the same motion as setting "_ _ _ 1" to [Pr. PD30] in the indexer method.
2. This will be the same motion as setting "_ _ _ 0" to [Pr. PD30] in the indexer method.
[Pr. PD30]
Operation status
ON
OFF
Part of droop
pulses
ON
OFF
Acceleration/
deceleration time
constant
+
S-pattern
acceleration/
deceleration time
constant
Acceleration/
deceleration
time constant
Decelerates to stop.
Part of S-pattern
acceleration/
deceleration time
constants
+
Part of droop
pulses
Part of droop
pulses
ON
OFF
www.kavrammuhendislik.com.tr
Stop method selection for LSP (Forward rotation stroke end) off or LSN
(Reverse rotation stroke end) off
0: Quick stop (home position erased)
1: Slow stop (home position erased)
2: Slow stop (deceleration to a stop by deceleration time constant)
3: Quick stop (stop by clearing remaining distance)
During deceleration to a stop
No S-pattern acceleration/
deceleration
With S-pattern acceleration/
deceleration
Servo motor speed
(linear servo motor
speed)
0 r/min
(0 mm/s)
LSP
ON
or
OFF
LSN
No S-pattern acceleration/
deceleration
With S-pattern acceleration/
deceleration
Servo motor speed
(linear servo motor
speed)
0 r/min
(0 mm/s)
LSP
ON
or
OFF
LSN
No S-pattern acceleration/
deceleration
With S-pattern acceleration/
deceleration
Servo motor speed
(linear servo motor
speed)
0 r/min
(0 mm/s)
LSP
ON
or
OFF
LSN
No S-pattern acceleration/
deceleration
With S-pattern acceleration/
deceleration
Servo motor speed
(linear servo motor
speed)
0 r/min
(0 mm/s)
LSP
ON
or
OFF
LSN
7 - 98
Remark
Erases the droop
pulses and stops the
motor.
Erases the home
position.
A difference will be
generated between
command position
and current position.
Perform a home
position return again.
Erases the droop
pulse portion and
stops the motor.
Erases the home
Part of
droop
position.
pulses
A difference will be
generated between
command position
and current position.
Perform a home
position return again.
Decelerates to a stop
with the deceleration
time constant
currently selected with
the point table or the
program.
Continues
Continues operation
deceleration
to stop.
for a delay portion of
the S-pattern
acceleration/decelera
tion time
constants. Maintains
the home position.
Erases the droop
Part of S-pattern
acceleration/
pulse portion and
deceleration time
constants
stops the motor.
+
Part of droop
Continues operation
pulses
for a delay portion of
Part of droop
pulses
the S-pattern
acceleration/decelera
tion time
constants. Maintains
the home position.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-j4-03a6-rj

Table of Contents