12. APPLICATION OF FUNCTIONS
(b) Degree unit
When the unit is set to [degree], the setting range of the current position latch is from 0 degree
(upper limit) to 359.999 degrees (lower limit).
When you set a value other than 0 degree to 359.999 degrees in the current position latch +/- [Pr.
PC66] to [Pr. PC69], the set value is converted as follows.
Current position latch range
After conversion
360.000 degrees to 999.999 degrees
(Setting value) % 360
-0.001 degrees to -359.999 degrees
360 + (setting value)
-360.000 degrees to -999.999 degrees
(setting value) % 360 + 360
The valid range of the current position latch varies depending on the setting of the upper and lower
limits.
The valid range remains unchanged even if the rotation direction is reversed.
0
0
CCW
CCW
Upper limit
Lower limit
value
value
Effective range
Upper limit
Lower limit
value
value
270
270
90
90
Effective range
180
180
Upper limit value > Lower limit value
Lower limit value > Upper limit value
To enable the current position latch function of section A in the figure, set the parameters as follows:
Current position latch range -: 315.000 degrees ([Pr. PC68]: 0, [Pr. PC69]: 315)
Current position latch range +: 90.000 degrees ([Pr. PC66]: 0, [Pr. PC67]: 90)
To enable the current position latch function of section B in the figure, set the parameter as follows:
Current position latch range -: 90.000 degrees ([Pr. PC68]: 0, [Pr. PC69]: 90)
Current position latch range +: 315.000 degrees ([Pr. PC66]: 0, [Pr. PC67]: 315)
0
CCW
315
Section A
90
Section B