7. PARAMETERS
No./
Setting
symbol/name
digit
PD42
_ x _ _
_ _ _ x (BIN): DI0 (point table No/Program No./next station No. selection 1)
(HEX)
*DIA4
0: Disabled (Use for an external input signal.)
Input signal
1: Enabled (automatic on)
automatic on
_ _ x _ (BIN): DI1 (point table No/program No./next station No. selection 2)
selection 4
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ x _ _ (BIN): DI2 (point table No/program No./next station No. selection 3)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _ (BIN): DI3 (point table No/program No./next station No. selection 4)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _
_ _ _ x (BIN): DI4 (point table No/Program No./next station No. selection 5)
(HEX)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ _ x _ (BIN): DI5 (point table No/program No./next station No. selection 6)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ x _ _ (BIN): DI6 (point table No/program No./next station No. selection 7)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _ (BIN): DI7 (point table No/program No./next station No. selection 8)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
Convert the setting value into hexadecimal as follows.
0
Function
Input device
RT (Second acceleration/deceleration selection)
RTCDP (Second acceleration/deceleration gain selection)
Input device
DI0 (Point table No/Program No./Next station No. selection 1)
DI1 (Point table No/Program No./Next station No. selection 2)
DI2 (Point table No/Program No./Next station No. selection 3)
DI3 (Point table No/Program No./Next station No. selection 4)
Input device
DI4 (Point table No/Program No./Next station No. selection 5)
DI5 (Point table No/Program No./Next station No. selection 6)
DI6 (Point table No/Program No./Next station No. selection 7)
DI7 (Point table No/Program No./Next station No. selection 8)
BIN 0: Use for an external input signal.
BIN 1: Automatic on
7 - 66
www.kavrammuhendislik.com.tr
Control mode
Initial
value
[unit]
0h
0h
Initial value
BIN HEX
0
0
0
0
0
Initial value
BIN HEX
0
0
0
0
0
Initial value
BIN HEX
0
0
0
0
0