7. PARAMETERS

7.4 Software limit

The limit stop with the software limit ([Pr. PT15] to [Pr. PT18]) is the same as the motion of the stroke
end. Exceeding a setting range will stop and servo-lock the shaft. This will be enabled at power-on and will be
disabled at home position return. Setting a same value to "Software limit +" and "Software limit -" will disable
this function. Setting a larger value to "Software limit -" than "Software limit +" will trigger [AL. 37.2 Parameter
combination error].
The software limit is disabled in the indexer method.
Inhibited range
Movable range
Travel
Travel possible
impossible
Current position
Software limit