Mitsubishi Electric MELSERVO-J4 Series Instruction Manual page 325

General-purpose interface ac servo. servo amplifier
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

7. PARAMETERS
No./
Setting
symbol/name
digit
PA08
_ _ _ x Gain adjustment mode selection
ATU
Select the gain adjustment mode.
Auto tuning
0: 2 gain adjustment mode 1 (interpolation mode)
mode
1: Auto tuning mode 1
2: Auto tuning mode 2
3: Manual mode
4: 2 gain adjustment mode 2
Refer to table 7.2 for details.
_ _ x _ For manufacturer setting
_ x _ _
x _ _ _
Setting
Gain adjustment mode
value
_ _ _ 0 2 gain adjustment
_ _ _ 1 Auto tuning mode 1
_ _ _ 2 Auto tuning mode 2
_ _ _ 3 Manual mode
_ _ _ 4 2 gain adjustment
Table 7.2 Gain adjustment mode selection
[Pr. PB06 Load to motor inertia ratio]
mode 1 (interpolation
[Pr. PB08 Position loop gain]
mode)
[Pr. PB09 Speed loop gain]
[Pr. PB10 Speed integral compensation]
[Pr. PB06 Load to motor inertia ratio]
[Pr. PB07 Model loop gain]
[Pr. PB08 Position loop gain]
[Pr. PB09 Speed loop gain]
[Pr. PB10 Speed integral compensation]
[Pr. PB07 Model loop gain]
[Pr. PB08 Position loop gain]
[Pr. PB09 Speed loop gain]
[Pr. PB10 Speed integral compensation]
[Pr. PB08 Position loop gain]
mode 2
[Pr. PB09 Speed loop gain]
[Pr. PB10 Speed integral compensation]
www.kavrammuhendislik.com.tr
Function
Automatically adjusted parameter
7 - 20
Control mode
Initial
value
[unit]
1h
0h
0h
0h

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-j4-03a6-rj

Table of Contents