Mitsubishi Electric MELSERVO-J4 Series Instruction Manual page 289

General-purpose interface ac servo. servo amplifier
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

6. HOW TO USE INDEXER
(4) Timing chart
The following timing chart shows that an operation is performed at a stop of the station No. 0 when
servo-on.
Number of stations: 8
Power supply
ALM (Malfunction)
MEND (Travel completion)
PS0 (Station output 1) to
PS7 (Station output 8)
(Note 5)
DI0 (Next station No. selection 1) to
DI7 (Next station No. selection 8)
Forward rotation
0 r/min
Servo motor speed
Reverse rotation
ST1 (Forward rotation start)
SIG (External limit/
Rotation direction decision/
Automatic speed selection)
RT (Second acceleration/
deceleration selection)
MD0
(Operation mode selection 1)
MD1
(Operation mode selection 2)
Torque limit
POINT
Always perform a home position return. Executing positioning operation without
home position return will trigger [AL. 90 Home position return incomplete
warning] and ST1 (Forward rotation start) will be disabled.
When travel distances are the same to a target station position from CCW and
from CW, the shaft will rotate to the station No. increasing direction.
4
3
5
2
6
7
1
0
ON
OFF
ON
OFF
ON
OFF
All off (Note 4)
Next station No. 1
5 ms or longer
[Pr. PC01]
[Pr. PC02]
setting time
setting time
Station position
No. 1
Automatic operation speed 1
5 ms or
5 ms or
longer
longer
ON
OFF
Ignored
(Note 1)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Torque limit value of
[Pr. PA11] and [Pr. PA12]
Torque limit value of
[Pr. PC35]
6 - 14
www.kavrammuhendislik.com.tr
4
3
5
2
6
7
1
0
Station output 1
All off (Note 4)
Next station No. 3
Station position
No. 3
Automatic operation
speed 2
5 ms or
longer
[Pr. PT39] setting time (Note 3)
Torque limit value of
[Pr. PA11] and [Pr. PA12]
Torque limit value of
[Pr. PC35]
4
3
5
2
6
7
1
0
Station output 3
All off (Note 4)
Station
output 1
Next station No. 1
Automatic operation
speed 1
Station position
No. 1
[Pr. PC30]
[Pr. PC31]
setting time
setting time
Ignored
(Note 2)
Torque limit value of
[Pr. PA11] and [Pr. PA12]
Torque limit value of
[Pr. PC35]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-j4-03a6-rj

Table of Contents