3. DISPLAY AND OPERATION SECTIONS
3.1.6 Parameter mode
(1) Parameter mode transition
After selecting the corresponding parameter mode with the "MODE" button, pressing the "UP" or
"DOWN" button changes the display as shown below.
To status display
From alarm mode
mode
Basic setting
Gain/filter
Extension setting
parameters
parameters
[Pr. PA01]
[Pr. PB01]
[Pr. PA02]
[Pr. PB02]
[Pr. PA31]
[Pr. PB63]
[Pr. PA32]
[Pr. PB64]
(2) Operation method
(a) Parameters of 5 or less digits
The following example shows the operation procedure performed after power-on to change the
control mode to the positioning mode (point table method) with [Pr. PA01 Operation mode]. Press
"MODE" to switch to the basic setting parameter screen.
To shift to the next parameter, press the "UP" or "DOWN" button.
When changing the [Pr. PA01] setting, change its setting value, then switch power off once and
switch it on again to enable the new value.
MODE
I/O setting
Extension setting 2
parameters
parameters
parameters
[Pr. PC01]
[Pr. PD01]
[Pr. PE01]
[Pr. PC02]
[Pr. PD02]
[Pr. PE02]
[Pr. PC79]
[Pr. PD47]
[Pr. PE63]
[Pr. PC80]
[Pr. PD48]
[Pr. PE64]
www.kavrammuhendislik.com.tr
Extension setting 3
Linear/DD motor
parameters
setting parameter
[Pr. PF01]
[Pr. PL01]
[Pr. PF02]
[Pr. PL02]
[Pr. PF47]
[Pr. PL47]
[Pr. PF48]
[Pr. PL48]
The parameter number is displayed.
Press "UP" or "DOWN" to change the number.
Press "SET" twice.
The set value of the specified parameter number flickers.
Press the "UP" button six times.
During flickering, the set value can be changed.
Use "UP" or "DOWN".
( _ _ _ 6: Positioning mode (point table method))
Press "SET" to enter.
3 - 21
Option setting
Positioning
parameters
control parameters
[Pr. Po01]
[Pr. PT01]
[Pr. Po02]
[Pr. PT02]
UP
DOWN
[Pr. Po31]
[Pr. PT47]
[Pr. Po32]
[Pr. PT48]