Mitsubishi Electric MELSERVO-J4 Series Instruction Manual page 367

General-purpose interface ac servo. servo amplifier
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

7. PARAMETERS
No./
Setting
symbol/name
digit
PD29
Select a filter for the input signal.
*DIF
_ _ _ x Input signal filter selection
Input filter
If external input signal causes chattering due to noise, etc., input filter is used to
setting
suppress it.
0: None
1: 0.888 [ms]
2: 1.777 [ms]
3: 2.666 [ms]
4: 3.555 [ms]
5: 4.444 [ms]
6: 5.333 [ms]
_ _ x _ RES (Reset) dedicated filter selection
0: Disabled
1: Enabled (50 [ms])
_ x _ _ CR (Clear) dedicated filter selection
0: Disabled
1: Enabled (50 [ms])
x _ _ _ For manufacturer setting
Function
7 - 62
www.kavrammuhendislik.com.tr
Control mode
Initial
value
[unit]
4h
0h
0h
0h