Using Forward/Reverse Rotation Stroke End To Change The Stopping Pattern; Alarm History Clear - Mitsubishi Electric MR-J2S-A Instruction Manual

Servo amplifier
Hide thumbs Also See for MR-J2S-A:
Table of Contents

Advertisement

5. PARAMETERS

5.2.3 Using forward/reverse rotation stroke end to change the stopping pattern

The stopping pattern is factory-set to make a sudden stop when the forward/reverse rotation stroke end is
made valid. A slow stop can be made by changing the parameter No. 22 value.
Parameter No.22 Setting
0
(initial value)
1

5.2.4 Alarm history clear

The servo amplifier stores one current alarm and five past alarms from when its power is switched on
first. To control alarms which will occur during operation, clear the alarm history using parameter No.16
before starting operation.
Clearing the alarm history automatically returns to "
After setting, this parameter is made valid by switch power from OFF to ON.
Sudden stop
Position control mode : Motor stops with droop pulses cleared.
Speed control mode
: Motor stops at deceleration time constant of zero.
Slow stop
Position control mode : The motor is decelerated to a stop in accordance with the
parameter No. 7 value.
Speed control mode
: The motor is decelerated to a stop in accordance with the
parameter No. 12 value.
Parameter No.16
Alarm history clear
0: Invalid (not cleared)
1: Valid (cleared)
5 - 33
WWW.NNC.IR
Stopping method
0 ".

Hide quick links:

Advertisement

Table of Contents
loading