7. PARAMETERS
No./
Setting
symbol/name
digit
Po08
Any output device can be assigned to the CN10-46 pin and CN10-47 pin.
*ODO1
_ _ x x
CN10-46 selection
MR-D01
Select an output signal function of the CN10-46 pin.
output device
Refer to table 7.15 for settings.
selection 1
This parameter setting is available with servo amplifiers with software version B7 or
later.
x x _ _
CN10-47 selection
Select an output signal function of the CN10-47 pin.
Refer to table 7.15 for settings.
This parameter setting is available with servo amplifiers with software version B7 or
later.
Function
7 - 78
www.kavrammuhendislik.com.tr
Control mode
Initial
value
[unit]
26h
27h