11. MR-D01 EXTENSION I/O UNIT

11.9.3 PS7DW-20V14B-F (Junction terminal block) (recommended)

(1) Usage
Always use the PS7DW-20V14B-F (Junction terminal block) (Toho Technology Corp.) with the option
cable (MR-J2HBUS_M) as a set. A connection example is shown below.
Ground the option cable on the junction terminal block side with AERSBAN-ESET (cable clamp fitting).
For how to use the cable clamp fitting, refer to section 11.14 (2) (c) of "MR-J4-_A_(-RJ) Servo Amplifier
Instruction Manual".
(2) Connection of MR-J2HBUS_M cable and junction terminal block
MR-D01
AERSBAN-ESET
(Cable clamp fitting)
CN20
MR-J2HBUS_M
MR-D01
(Note 1) MR-J2HBUS_M
CN20
1
1
2
OVC
2
3
3
OMO1
4
4
5
5
6
6
7
7
8
8
LG
9
9
10
10
LG
11
11
OTLA
12
12
P15R
13
13
OMO2
14
14
N12R
15
15
16
16
17
17
18
18
19
19
20
20
SD
Shell
Shell
Connector: 10120-6000EL (3M)
Shell kit: 10320-3210-000 (3M)
Note 1. Symbol indicating cable length is put in _.
05: 0.5 m
1: 1 m
5: 5 m
2. Do not connect anything to the terminal where no signal has been assigned.
11 - 75
www.kavrammuhendislik.com.tr
PS7DW-20V14B-F
(Junction terminal block)
PS7DW-20V14B-F
(Junction terminal block)
CN
(Note 2) Terminal block
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
19
19
20
20
Shell Shell
1
2
OVC
3
4
OMO1
5
6
7
8
9
LG
10
11
LG
12
OTLA
13
P15R
14
OMO2
15
N12R
16
17
18
19
20
SD
E

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-j4-03a6-rj