Mitsubishi Electric MELSERVO-J4 Series Instruction Manual page 115

General-purpose interface ac servo. servo amplifier
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

3. DISPLAY AND OPERATION SECTIONS
(3) Operation method
(a) Setting of 3 or less digits
The following example is the operation method at power-on to set "1" to the auxiliary function of the
point table No. 1.
Press the "UP" or "DOWN" button to switch to other item of the same point table No.
Press the "MODE" button to switch to the next point table No.
POINT
After changing and defining the setting values of the specified point table, the
defined setting values of the point table are displayed. To discard the changed
setting, press the "MODE" button for 2 s or more. The setting before the change
will be displayed. Keep pressing the "UP" or "DOWN" button to continuously
change the most significant digit of the setting values.
To the next item setting
3 - 42
www.kavrammuhendislik.com.tr
Press the "MODE" button four times.
......A point table No. is displayed.
Press the "UP" or "DOWN" button to select
point table No. 1.
Press the "SET" button once.
Press the "UP" button five times.
Press the "SET" button twice.
......The setting value of auxiliary function of specified point table
No. flickers.
Press the "UP" button once.
......During flickering, the set value can be changed.
Set using the "UP" or "DOWN" button.
Press "SET" to enter.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-j4-03a6-rj

Table of Contents