3. DISPLAY AND OPERATION SECTIONS
Name
Servo motor series ID
Servo motor type ID
Servo motor encoder ID
For manufacturer adjustment
For manufacturer adjustment
Teaching function
Display
"SET"
"SET"
"SET"
Refer to section 3.2.10.
3 - 37
www.kavrammuhendislik.com.tr
Description
Displays the series ID of the servo motor
currently connected.
Press the "SET" button to show the lower 3
digits of servo motor series ID.
For indication details, refer to app. 1 of "Servo
Motor Instruction Manual (Vol. 3)".
Press the "UP" or "DOWN" button to shift to
the next diagnosis menu.
Displays the type ID of the servo motor
currently connected.
Press the "SET" button to show the lower 3
digits of servo motor type ID.
For indication details, refer to app. 1 of "Servo
Motor Instruction Manual (Vol. 3)".
Press the "UP" or "DOWN" button to shift to
the next diagnosis menu.
Displays the servo motor encoder ID of the
servo motor currently connected.
Press the "SET" button to show the lower 3
digits of servo motor encoder ID.
For indication details, refer to app. 1 of "Servo
Motor Instruction Manual (Vol. 3)".
Press the "UP" or "DOWN" button to shift to
the next diagnosis menu.
This is for manufacturer adjustment.
This is for manufacturer adjustment.
After an operation travels to a target position
(MEND (Travel completion) is turned on) with
a JOG operation or manual pulse generator
operation, pushing the "SET" button of the
operation area or turning on TCH (Teach) will
import the position data. This function is
available only in the point table method. In
other control modes, the display remains the
same.