Software Limit - Mitsubishi Electric MR-J4-TM Instruction Manual

Servo amplifier melservo-j4
Hide thumbs Also See for MR-J4-TM:
Table of Contents

Advertisement

5. PARAMETERS

5.3 Software limit

The limit stop with the software limit ([Pr. PT15] to [Pr. PT18]) is the same as the motion of the stroke end.
Exceeding a setting range will stop and servo-lock the shaft. This will be enabled at power-on and will be
disabled in the velocity mode, torque mode, and homing mode. Setting a same value to "Software limit +"
and "Software limit -" will disable this function. Setting a larger value to "Software limit -" than "Software limit
+" will disable this function.
Inhibited range
Movable range
Travel
Travel possible
impossible
Current position
Software limit
5 - 83