Result
Once a transducer has been installed, it is listed in the
the information you have collected about the transducer, select the relevant transducer
in the list.
The
functionality on the
Edit
the information you have provided for the transducer. You cannot change the model
identification and the serial number. The custom name is used several places in the user
interface, and it can be changed.
The
functionality on the
Remove
the information you have provided for the transducer. There is no "undo" functionality.

Installing transceiver channels

In order to use the ES80, the Processor Unit must be connected to one or more
transceivers, and each of them must in turn be connected to one or more transducers.
Each channel must be installed before it can be put to use. In this context, the phrase
channel is used as a common term to identify the combination of transceiver, transducer
and operating frequency.
Prerequisites
The ES80 is installed as specified in the ES80 Installation manual.
• All cables are connected and tested.
• Each transceiver is powered up.
• The software license for each transceiver is installed and activated.
• The Ethernet adapter in the Processor Unit is set up with a unique IP address.
• All relevant transducers are installed using the
Context
The
Transceiver Installation
transceivers. Every time the page is opened, the ES80 software automatically performs a
search on the Ethernet network for transceivers.
The list in the upper part on the
of the transceivers and channels that are currently available. In this context, the phrase
channel is used as a common term to identify the combination of transceiver, transducer
and operating frequency. Each channel is identified by the transceiver type and serial
number and the transducer(s) in use. The current status for each channel is also provided.
: The channel is already in use, probably by another echo sounder on the same
Busy
network. You cannot connect to this channel.
: This channel is connected to your ES80 system.
Installed
: This channel cannot be used.
Lost
406273/C
Transducer Installation
Transducer Installation
parameters control the installation and disconnection of
Transceiver Installation
Installed Transducers
page makes it possible to change
page makes it possible to delete
page.
Transducer
page shows you an overview
Getting started