Selecting echogram views on the bottom bar

The bottom bar in the ES80 presentation allows you to select which echogram views you
wish to see, and how these are organized. The number of tabs available on the bottom
bar depends on how many channels your ES80 has.
Context
The bottom bar is available all the time. The tabs on the bottom bar allows you to choose
channel and presentation mode. A dedicated tab provides a special view for you to see
the screen captures you have made. The bottom bar also shows you the current colour
scale, as well as the time and date.
The number of tabs available on the bottom bar depends on how many channels your
ES80 has. Two tab "groups" allow you to select channels and views. This example shows
the ES80 with two channels. In this context, the phrase channel is used as a common
term to identify the combination of transceiver, transducer and operating frequency.
The tabs on the bottom bar allows you to control the echogram presentation.
Selecting presentation modes
Three presentation modes are available when you wish to see all the echogram
channels simultaneously in the ES80 presentation. The three tabs will arrange the
echogram views vertically, horizontally, or in rectangular rows and columns.
The
and
Vertical
Horizontal
use on your ES80. The
By default, the echogram views are automatically arranged in the ES80 presentation.
You can click and drag the border of each individual view to change its size. The size
of the other views are reduced accordingly.
Selecting individual echogram channels
Each channel is shown with a dedicated tab. The channel is identified with the name
of the transducer in use. This name is the custom name you provided when you
installed the transducer. Select a specific transducer tab to see only that channel in the
ES80 presentation. In this context, the phrase channel is used as a common term to
identify the combination of transceiver, transducer and operating frequency.
Procedure
Observe the bottom bar at the bottom of the ES80 presentation.
Select the appropriate tab to set up the presentation of the echogram views.
Select
A
Square
Click the name of a transducer to see the relevant echogram. The echograms
B
from the other channels are hidden.
108
tabs are only shown if you have two or more channels in
tab is only shown if you have three or more channels.
Square
,
or
Vertical
Horizontal
to arrange the echogram views accordingly.