Simrad ES80 Reference Manual page 36

Wideband fish finding echo sounder
Table of Contents

Advertisement

Simrad ES80 Reference Manual
4
On the left side, select
On the
Installed Transducers
page opens with all settings unavailable. This is a safety precaution to
Transducer
prevent unintentional changes to the transducer settings. To make any changes, you
must select
Edit
5
Verify that each transducer has been installed with all settings defined.
The physical location of the ES80 transducer is important for the ES80 data
accuracy. The offset value for "X" defines the vertical location (the depth) of the
transducer face.
This is the installation depth of the transducer; the vertical location of the transducer
face relative to the water surface. In order to measure correct water depth, the
ES80 needs to know the vertical distance between the vessel's water line and the
acoustic face of each transducer. The depth of each individual transducer must be
defined manually. Enter the depth as a positive number. If the displacement of your
vessel changes considerably, you may consider changing this parameter often. For
accurate location of the transducer, you need the detailed vessel drawings.
6
On the left side of the
Observe that the
7
Check that all applicable transceivers and transducers are connected and operational.
For each transceiver, this is indicated by the green label with text "Installed".
8
Close the
Installation
The purpose of the
Normal Operation
the current transceiver parameters. It also allows you to change these parameters to
match your current operational requirements.
9
Open the
Operation
10 On the
Operation
11 For each channel (if necessary):
a
Set
Pulse Type
transducer.
b
Set
to Active.
Mode
c
Set
Pulse Duration
d
Set
to the correct power level for the transducer.
Power
e
Set
Start Frequency
and the transducer.
In this context, the phrase channel is used as a common term to identify the
combination of transceiver, transducer and operating frequency.
12 Close the dialog box.
34
Transducer Installation
list, select one of the transducers. Observe that the
.
dialog box, select
Installation
Transceiver Installation
dialog box without making any changes.
dialog box is to provide you with an overview of
menu.
menu, open the
Normal Operation
to a LFM or CW mode as permitted by your license and the
to your chosen value.
and
End Frequency
.
Transceiver
page opens.
dialog box.
to values permitted by your license
.
406273/C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents