Egr Thermostat Housing - Detroit Diesel MBE 4000 Service Manual

Hide thumbs Also See for MBE 4000:
Table of Contents

Advertisement

4.6

EGR THERMOSTAT HOUSING

www.rtrucks.ru
4.6

EGR THERMOSTAT HOUSING

The thermostat for the EGR engine has the same removal, installation, and checking instructions
as for the non-EGR engine (refer to section 4.5), but the thermostat housing cover is different by
design to accommodate the EGR modulated control valve mounting. See Figure 4-17.
1. EGR Modulated Valve Mounting Holes
Figure 4-17
4.6.1
EGR Thermostat Housing Cover Removal
Remove the EGR thermostat housing cover as follows:
1. Remove the four bolts that attach the EGR modulated control valve to the housing cover
and remove the valve.
2. Remove the three thermostat housing cover mounting bolts.
3. Remove the two bolts that attach the reed valve housing bracket to thermostat cover.
Remove bracket.
4. Remove any other hose or fitting connections.
4.6.2
EGR Thermostat Housing Cover Installation
Install the EGR thermostat housing cover as follows:
4-30
www.rtrucks.ru
EGR Thermostat Housing Cover
www.rtrucks.ru
2. Thermostat Housing Cover Mounting Holes
6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION