Detroit Diesel MBE 4000 Service Manual page 467

Hide thumbs Also See for MBE 4000:
Table of Contents

Advertisement

www.rtrucks.ru
9. Remove the four bolts attaching the EGR control valve to the thermostat housing.
See Figure 7-39.
1. EGR Control Valve Mounting Bolts
2. Wiring Harness Terminal
Figure 7-39
10. Pull the EGR control valve out of the reed valve housing flange.
11. Remove symmetric membrane from the housing flange. See Figure 7-38.
All information subject to change without notice.
6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION
www.rtrucks.ru
www.rtrucks.ru
Removal or Installation of EGR Control Valve
www.rtrucks.ru
MBE 4000 SERVICE MANUAL
3. EGR Control Valve
4. EGR Temperature Sensor
www.rtrucks.ru
7-47
www.rtrucks.ru

Advertisement

Table of Contents
loading

Table of Contents