Detroit Diesel MBE 4000 Service Manual page 533

Hide thumbs Also See for MBE 4000:
Table of Contents

Advertisement

www.rtrucks.ru
6. Using the cranking tool (J 46167 or 407 589 00 63 00), turn the crankshaft until cylinder
#6 is at the ignition TDC position (all valves are closed) and cylinder #1 is at the valve
overlap position (all valves are open).
7. Using the same procedure, check the valves in the "Valve Overlap" row
listed in Table 12-3and adjust them (if necessary), using the procedures under the headings
"Checking Valve Lash" and "Adjusting Valve Lash."
8. For each valve, measure the valve lash with a feeler gauge between the rocker arm and
valve bridge. It should be possible to pull the feeler gauge through with no more than
light resistance.
9. If the value measured is within the range listed in Table 12-4 in the "Check For" column,
check the next valve.
Valve Type
Intake
Exhaust
Table 12-4
If the value measured is outside the range given in the "Check For" column listed in Table 12-2,
adjust the valve lash.
All information subject to change without notice.
6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION
www.rtrucks.ru
www.rtrucks.ru
Check For: mm (inches)
0.30 to 0.60 (0.012 to 0.024)
0.50 to 0.80 (0.020 to 0.032)
Valve Lash Checking and Adjustment
www.rtrucks.ru
MBE 4000 SERVICE MANUAL
www.rtrucks.ru
Adjust to: mm (inches)
0.40 (0.016)
0.60 (0.024)
www.rtrucks.ru
12-9