12. Remove the thermostat housing from the coolant pump.
4.2.2
Disassemble the coolant pump unit as follows:
1. Remove the coolant pump from the engine. Refer to section 4.2.1.
2. Using a puller, pull the coolant pump hub away from the bearing. See Figure 4-5.
1. Puller
2. Hub
Figure 4-5
All information subject to change without notice.
6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION
www.rtrucks.ru
Coolant Pump Disassembly
Pulling the Hub
www.rtrucks.ru
3. Coolant Pump Housing