Detroit Diesel MBE 4000 Service Manual page 455

Hide thumbs Also See for MBE 4000:
Table of Contents

Advertisement

www.rtrucks.ru
1. Install coolant outlet pipe. Install the two M8 x 25 mm bolts through the coolant pipe
flange, metal gasket and into the coolant pump. Leave loose until the cooler assembly is
installed, then torque bolts to 35 N·m (26 lb·ft). See Figure 7-27.
1. Coolant Outlet Pipe Bolts
2. Coolant Vent Line
3. Membrane
Figure 7-27
NOTE:
Coolant outlet pipe must be installed to coolant pump before the EGR cooler support
and cooler are installed.
All information subject to change without notice.
6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION
www.rtrucks.ru
www.rtrucks.ru
Installation of Coolant Outlet Pipe
www.rtrucks.ru
MBE 4000 SERVICE MANUAL
4. EGR Coolant Outlet Pipe
5. Coolant Outlet Pipe Bracket
www.rtrucks.ru
7-35
www.rtrucks.ru

Advertisement