13.4.7
Reset Absolute Encoder (Fn008)
Refer to the following section for information on this utility function other than the procedure.
5.17 Resetting the Absolute Encoder on page 5-51
Panel Display after
Step
Operation
1
2
3
4
5
6
7
8
To enable the change to the settings, turn the power supply to the SERVOPACK OFF and ON again.
13.4 Utility Function (Fn) Operations on the Panel Operator
Keys
Press the MODE/SET Key to enter Utility Function
Mode.
MODE/SET
DATA/
Press the UP Key or DOWN Key to display Fn008.
MODE/SET
DATA/
Press the DATA/SHIFT Key for approximately one
second. PGCL1 will be displayed.
MODE/SET
Continue pressing the UP Key until PGCL5 is dis-
played.
Note: If you press the wrong key, no-oP will flash
on the display for approximately one second
MODE/SET
DATA/
and the display will return to the original Util-
ity Function Mode display. Repeat the opera-
tion from the beginning.
Press the MODE/SET Key.
The absolute encoder will be initialized.
When initialization has been completed, donE will
MODE/SET
DATA/
flash on the display for approximately one second.
After displaying donE, the display will return to the
–
PGCL5 display.
Press the DATA/SHIFT Key for approximately one
second to return the display to Fn008.
MODE/SET
13.4.7 Reset Absolute Encoder (Fn008)
Operation
13