Applicable Tools; Operating Procedure - YASKAWA SGD7S series Product Manual

Sigma-7-series ac servo drive. sigma-7s servopack with analog voltage/pulse train references
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

5.17 Resetting the Absolute Encoder

5.17.3 Applicable Tools

5.17.3 Applicable Tools

The following table lists the tools that you can use to reset the absolute encoder and the appli-
cable tool functions.
Panel Operator
Digital Operator
SigmaWin+

5.17.4 Operating Procedure

Use the following procedure to reset the absolute encoder.
1.
Confirm that the servo is OFF.
2.
Click the
3.
Select Absolute Encoder Reset in the Menu Dialog Box.
The Absolute Encoder Reset Dialog Box will be displayed.
4.
Click the Continue Button.
Click the Cancel Button to cancel resetting the absolute encoder. The Main Window will return.
5.
Click the Execute setting Button.
The current alarm code and name will be displayed in the Alarm name Box.
5-52
Tool
Fn008
Fn008
Setup
Absolute Encoder Reset
Servo Drive Button in the workspace of the Main Window of the SigmaWin+.
Function
Reference
13.4.7 Reset Absolute Encoder
(Fn008) on page 13-17
Σ-7-Series Digital Operator Operating
Manual (Manual No.: SIEP S800001
33)
5.17.4 Operating Procedure on page
5-52

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgd7s-****00a series

Table of Contents