Applicable Tools; Operating Procedure - YASKAWA SGD7S series Product Manual

Sigma-7-series ac servo drive. sigma-7s servopack with analog voltage/pulse train references
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

7.3 Trial Operation for the Servomotor without a Load

7.3.2 Applicable Tools

• Linear Servomotors
Pn383
Pn305
Pn306
Information
7.3.2

Applicable Tools

The following table lists the tools that you can use to perform jogging and the applicable tool
functions.
Panel Operator
Digital Operator
SigmaWin+
7.3.3

Operating Procedure

Use the following procedure to jog the motor.
1.
Click the
2.
Select JOG Operation in the Menu Dialog Box.
The Jog Operation Dialog Box will be displayed.
3.
Read the warnings and then click the OK Button.
7-8
Jogging Speed
Setting Range
0 to 10,000
Soft Start Acceleration Time
Setting Range
0 to 10,000
Soft Start Deceleration Time
Setting Range
0 to 10,000
When an absolute encoder is used, you do not need to input the SEN signal. It is always
active.
Tool
Function
Fn002
Fn002
Test Run - Jog
Servo Drive Button in the workspace of the Main Window of the SigmaWin+.
Setting Unit
Default Setting
1 mm/s
50
Setting Unit
Default Setting
1 ms
0
Setting Unit
Default Setting
1 ms
0
Operating Procedure Reference
13.4.2 Jog (Fn002) on page 13-13
Σ-7-Series Digital Operator Operating Manual (Manual
No.: SIEP S800001 33)
Operating Procedure on page 7-8
Speed
Position
Force
When Enabled
Classification
Immediately
Setup
Speed
When Enabled
Classification
Immediately
Setup
Speed
When Enabled
Classification
Immediately
Setup

Advertisement