YASKAWA SGD7S series Product Manual page 247

Sigma-7-series ac servo drive. sigma-7s servopack with analog voltage/pulse train references
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

 Precautions When Using a Linear Incremental Encoder from Magnes-
cale Co., Ltd.
 Encoder Divided Phase-C Pulse Output Selection
You can also output the encoder's phase-C pulse for reverse movement. To do so, set Pn081
to n.1.
Parameter

n.
0
(default setting)
Pn081

n.
1
Precautions on Setting the Phase-C Pulse Output Selection (Pn081 = n.X)
• If you set Pn081 to n.1 (Output phase-C pulses in both the forward and reverse direc-
tions), the width of the phase-C pulse output may be narrower than the width of the phase-A
Important
pulse.
• There is a difference of 1/8th of the scale pitch in the phase-C detection position for the
encoder's phase-C pulse output position between when Pn081 = n.X is set to 0 (Output
phase-C pulses only in the forward direction) and when it is set to 1 (Output phase-C pulses in
both the forward and reverse directions).
Movement in the forward direction

Pn081 = n.
0

Pn081 = n.
1
Observe the following precaution if you set Pn081 to n.0 (Output phase-C pulses only in
the forward direction).
When a linear incremental encoder from Magnescale Co., Ltd. is used, the count direction of
the encoder determines how the phase-C pulse (CN1-19 and CN1-20) is output.
Note: The count direction (up or down) of the linear encoder determines whether a phase-C pulse is output. The
output of the pulse does not depend on the setting of the movement direction (Pn000 = n.1).
Encoder Model
Interpolator
SL710
PL101-RY
SL720
MJ620-T13
SL730
SR75
SR85
MQ10-FLA
SQ10
MQ10-GLA
Meaning
Output phase-C pulses only in the forward
direction.
Output phase-C pulses in both the forward
and reverse directions.
One linear encoder pitch
Origin
1/8 linear encoder pitch
Origin
Linear Encoder Pitch [μm]
6.8 Encoder Divided Pulse Output
6.8.1 Encoder Divided Pulse Output Signals
When Enabled
After restart
800
800
800
80
80
400
Classification
Setup
6
6-49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgd7s-****00a series

Table of Contents