Parameter
Name
No.
Input Signal Selections
2
6
SEN (Absolute Data Request Input) Signal Allocation

n.
X
/PSEL (Reference Pulse Input Multiplication Switching Input) Signal Allo-
Pn515
cation
n.X

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Setting
Setting
Range
Unit
0000 hex to
FFFF hex
0
Active when CN1-40 input signal is ON (closed).
1
Active when CN1-41 input signal is ON (closed).
2
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).
7
The signal is always active.
8
Enable when 5 V is input to CN1-4.
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42 input signal is OFF (open).
C
Active when CN1-43 input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46 input signal is OFF (open).
0
Active when CN1-40 input signal is ON (closed).
1
Active when CN1-41 input signal is ON (closed).
2
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).
7
The signal is always enabled.
8
The signal is always inactive.
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42 input signal is OFF (open).
C
Active when CN1-43 input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46 input signal is OFF (open).
14.1 List of Parameters
14.1.2 List of Parameters
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
8888
After
All
hex
restart
Continued on next page.
Classi-
Refer-
fication
ence
Setup
Reference
page 6-73
Reference
page 6-34
14