Setting The Multiturn Limit; Absolute Encoder Origin Offset - YASKAWA SGD7S-***A20****F62 Series Product Manual

Sigma-7-series ac servo drive, sigma-7s servopack with ft/ex specification for transfer and alignment application
Table of Contents

Advertisement

4.2 Setup Procedure

4.2.2 Setting the Multiturn Limit

4.2.2

Setting the Multiturn Limit

When you use an absolute encoder, set the multiturn limit to match the rotational coordinate
system that is used by the system.
When you use a rotational coordinate system, you must set the multiturn limit.
Refer to the following manual for details on setting the multiturn limit.
Σ
-7-Series
SIEP S800001 28)
Pn205
24 (PnA48)
Note: Turn the power supply OFF and ON again, or send the Setup Device command (CONFIG) from the host con-
troller to enable changes to these parameters.
Example
Important
4.2.3

Absolute Encoder Origin Offset

If you use an absolute encoder, you can set Pn808 (Absolute Encoder Origin Offset) to the off-
set between the encoder position and the machine coordinate system position (feedback posi-
tion (APOS)).
An example of when the encoder position (X) is at the origin of the machine coordinate system
(0) is provided below.
To set encoder position (X) at the origin of the machine coordinate system (0), the following
relationship must exist in the parameter settings: Pn87C ≤ Pn808 ≤ Pn87A.
Pn808 is set as follows:
• If the offset is smaller than the setting of Pn87C (First Rotational Coordinate): Pn808 = Offset
+ (Pn87A − Pn87C + 1)
4-4
Σ
-7S SERVOPACK with MECHATROLINK-III Communications References Product Manual (Manual No.:
Multiturn Limit
Setting Range
0 to 65,535
Multiturn Limit Setting
Setting Range
0 to 65,535
Setting Example for the Multiturn Limit (Pn205)
Turntable
Load shaft
Encoder: 20 bits
Conditions: A turntable is controlled with rotational coordinates where one revolution equals
360°, which is equal to 36,000 reference units.
First rotational coordinate (Pn87C): 0
Last rotational coordinate (Pn87A): 35,999
Gear ratio: 1/100
The electronic gear ratio is as follows:
With this gear ratio, the motor will turn 100 times for 1 revolution of the turntable. The Multi-
turn Limit (Pn205) is therefore 99 (100 − 1 = 99).
If the multiturn limit is not set to match the machine rotational coordinate system, the position
may become offset.
Setting Unit
Default Setting
1 rev
65535
Setting Unit
Default Setting
1 rev
65535
Gear ratio: 1/100
Gear
Motor
B
Pn20E
=
=
Pn21
A
When Enabled
Classification
After restart
When Enabled
Classification
After restart
104,857,600
36,000
Setup