13.4 Utility Function (Fn) Operations on the Panel Operator

13.4.21 Display SERVOPACK and Servomotor IDs (Fn01E)

Step
5
6
13.4.21 Display SERVOPACK and Servomotor IDs (Fn01E)
This function cannot be executed from the Panel Operator on the SERVOPACK.
13.4.22 Display Servomotor ID from Feedback Option Module
(Fn01F)
This function cannot be executed from the Panel Operator on the SERVOPACK.

13.4.23 Set Absolute Linear Encoder Origin (Fn020)

Refer to the following section for information on this utility function other than the procedure.
5.18.1 Setting the Origin of the Absolute Linear Encoder on page 5-54
Step
1
2
3
4
5
6
7
13-28
Panel Display after
Operation
MODE/SET
MODE/SET
Panel Display after
Operation
MODE/SET
MODE/SET
MODE/SET
MODE/SET
MODE/SET
MODE/SET
To enable the change to the settings, turn the power supply to the SERVOPACK OFF and ON again.
Keys
Wait for a period of time and then press the MODE/
SET Key again to complete vibration detection and
updating the setting. This will enable the setting. If the
setting is completed normally, donE will be displayed.
DATA/
If there was an error in making the setting, Error will be
displayed.
Press the DATA/SHIFT Key for approximately one sec-
ond to return the display to Fn01b.
DATA/
Keys
Press the MODE/SET Key to enter Utility Function
Mode.
DATA/
Press the UP Key or DOWN Key to display Fn020.
DATA/
Press the DATA/SHIFT Key for approximately one sec-
ond. The display shown at the left will appear.
DATA/
Continue pressing the UP Key until 0SET5 is dis-
played.
Note: If you make a mistake during key operations, no_oP will
DATA/
flash on the display for approximately one second and
then Fn000 will be displayed again.
Press the MODE/SET Key to set the origin of the
absolute linear encoder.
When the setting has been completed, donE will flash
DATA/
on the display, and then the display shown on the left
will appear again.
Press the DATA/SHIFT Key for approximately one sec-
ond to return the display to Fn020.
DATA/
Continued from previous page.
Operation
Operation