YASKAWA SGD7S series Product Manual page 578

Sigma-7-series ac servo drive. sigma-7s servopack with analog voltage/pulse train references
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

Parameter
Name
No.
Application Function
2
Selections 2
Speed/Position Control Option (T-REF Input Allocation)

n.
X
Torque Control Option (V-REF Input Allocation)

n.
X
Encoder Usage
Pn002

n.
X
External Encoder Usage

n.X
Setting
Setting
Range
Unit
0000 hex
to
4213
hex
0
Do not use T-REF.
1
Use T-REF as an external torque limit input.
2
Use T-REF as a torque feedback input.
Use T-REF as an external torque limit input when
3
/P-CL or /N-CL is ON.
0
Do not use V-REF.
1
Use V-REF as an external speed limit input.
Use the encoder according to encoder specifica-
0
tions.
1
Use the encoder as an incremental encoder.
Use the encoder as a single-turn absolute
2
encoder.
0
Do not use an external encoder.
The external encoder moves in the forward direc-
1
tion for CCW motor rotation.
2
Reserved setting (Do not use.)
The external encoder moves in the reverse direc-
3
tion for CCW motor rotation.
4
Reserved setting (Do not use.)
14.1 List of Parameters
14.1.2 List of Parameters
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
0000
After
hex
restart
Applicable
Motors
All
Applicable
Motors
All
Applicable
Motors
All
Rotary
Applicable
Motors
Rotary
Continued on next page.
Classi-
Refer-
fication
ence
Setup
Reference
page 6-67
page 8-87
page 6-69
Reference
page 6-45
Reference
page 6-73
Reference
page 10-6
14