List Of Alarms - YASKAWA SGD7S series Product Manual

Sigma-7-series ac servo drive. sigma-7s servopack with analog voltage/pulse train references
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

12.2 Alarm Displays

12.2.1 List of Alarms

Alarm
Number
A.041
A.042
A.044
A.050
A.051
A.070
A.080
A.0b0
A.100
A.101
A.300
A.320
A.330
A.400
A.410
A.510
12-6
Alarm Name
Encoder Output Pulse
Setting Error
Parameter Combination
Error
Semi-Closed/Fully-Closed
Loop Control Parameter
Setting Error
Combination Error
Unsupported Device
Alarm
Motor Type Change
Detected
Linear Encoder Pitch Set-
ting Error
Invalid Servo ON Com-
mand Alarm
Overcurrent Detected
Motor Overcurrent
Detected
Regeneration Error
Regenerative Overload
Main Circuit Power Supply
Wiring Error
Overvoltage
Undervoltage
Overspeed
Alarm Meaning
The setting of Pn212 (Num-
ber of Encoder Output
Pulses) or Pn281 (Encoder
Output Resolution) is outside
of the setting range or does
not satisfy the setting condi-
tions.
The combination of some
parameters exceeds the set-
ting range.
The settings of the Option
Module and Pn002 =
n.X (External Encoder
Usage) do not match.
The capacities of the
SERVOPACK and Servomo-
tor do not match.
An unsupported device was
connected.
The connected motor is a dif-
ferent type of motor from the
previously connected motor.
The setting of Pn282 (Linear
Encoder Scale Pitch) has not
been changed from the
default setting.
The /S-ON (Servo ON) signal
was input from the host con-
troller after a utility function
that turns ON the Servomo-
tor was executed.
An overcurrent flowed
through the power transistor
or the heat sink overheated.
The current to the motor
exceeded the allowable cur-
rent.
There is an error related to
regeneration.
A regenerative overload
occurred.
• The AC power supply input
setting or DC power supply
input setting is not correct.
• The power supply wiring is
not correct.
The main circuit DC voltage
is too high.
The main circuit DC voltage
is too low.
The motor exceeded the
maximum speed.
Continued from previous page.
Servo-
Alarm Code
Alarm
motor
Output
Reset
Stop-
Possi-
ping
ALO1 ALO2 ALO3
ble?
Method
Gr.1
No
H
Gr.1
No
H
Gr.1
No
H
Gr.1
Yes
H
Gr.1
No
H
Gr.1
No
H
Gr.1
No
H
Gr.1
Yes
H
Gr.1
No
L
Gr.1
No
L
Gr.1
Yes
L
Gr.2
Yes
L
Gr.1
Yes
L
Gr.1
Yes
H
Gr.2
Yes
H
Gr.1
Yes
L
Continued on next page.
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
L
H
L
H
L
H
H
L
H
L
H
L