Reset Option Module Configuration Error (Fn014); Initialize Vibration Detection Level (Fn01B) - YASKAWA SGD7S series Product Manual

Sigma-7-series ac servo drive. sigma-7s servopack with analog voltage/pulse train references
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

13.4.19 Reset Option Module Configuration Error (Fn014)

Refer to the following section for information on this utility function other than the procedure.
12.2.6 Resetting Alarms Detected in Option Modules on page 12-45
Panel Display after
Step
Operation
1
2
3
4
5
6
7
To enable the change to the setting, turn the power supply to the SERVOPACK OFF and ON again
8
after clearing detected Option Module alarms has been completed.

13.4.20 Initialize Vibration Detection Level (Fn01B)

Refer to the following section for information on this utility function other than the procedure.
6.15 Initializing the Vibration Detection Level on page 6-98
Panel Display after
Step
Operation
1
2
3
4
(Flashing)
13.4 Utility Function (Fn) Operations on the Panel Operator
13.4.19 Reset Option Module Configuration Error (Fn014)
Keys
Press the MODE/SET Key to enter Utility Function
Mode.
MODE/SET
DATA/
Press the UP Key or DOWN Key to display Fn014.
MODE/SET
DATA/
Press the DATA/SHIFT Key for approximately one sec-
ond. The display shown at the left will appear.
MODE/SET
DATA/
Press the UP Key or DOWN Key to select the Option
Module to be cleared.
MODE/SET
DATA/
Press the MODE/SET Key for approximately one sec-
ond. The display shown at the left will appear.
MODE/SET
DATA/
Press the MODE/SET Key again. The alarms in the
Option Module will be cleared.
donE will flash on the display and the display shown
MODE/SET
DATA/
on the left will appear again.
Press the DATA/SHIFT Key for approximately one sec-
ond to return the display to Fn014.
MODE/SET
DATA/
Keys
Press the MODE/SET Key to enter Utility Function
Mode.
MODE/SET
DATA/
Press the UP Key or DOWN Key to display Fn01b.
MODE/SET
DATA/
Press the DATA/SHIFT Key for approximately one sec-
ond. The display shown at the left will appear.
MODE/SET
DATA/
Press the MODE/SET Key for approximately one sec-
ond. The display shown on the left will flash and the
vibration level will be detected and updated.
Note: 1. Operate the SERVOPACK with the references that
MODE/SET
DATA/
2. If the Servomotor operates at 10% or less of the
Operation
Operation
will be used for actual operation.
maximum speed, Error will be displayed.
Continued on next page.
13
13-27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgd7s-****00a series

Table of Contents