Resetting Motor Type Alarms (Fn021); Software Reset (Fn030); Polarity Detection (Fn080) - YASKAWA SGD7S series Product Manual

Sigma-7-series ac servo drive. sigma-7s servopack with analog voltage/pulse train references
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

13.4.24 Resetting Motor Type Alarms (Fn021)

Refer to the following section for information on this utility function other than the procedure.
12.2.7 Resetting Motor Type Alarms on page 12-47
Panel Display after
Step
Operation
1
2
3
4
5
6
To enable the change to the settings, turn the power supply to the SERVOPACK OFF and ON again.

13.4.25 Software Reset (Fn030)

Refer to the following section for information on this utility function other than the procedure.
6.14 Software Reset on page 6-96
Panel Display after
Step
Operation
1
2
3
4
5

13.4.26 Polarity Detection (Fn080)

Refer to the following section for information on this utility function other than the procedure.
5.11 Polarity Detection on page 5-27
Panel Display after
Step
Operation
1
13.4 Utility Function (Fn) Operations on the Panel Operator
Keys
Press the MODE/SET Key to enter Utility Function
Mode.
MODE/SET
DATA/
Press the UP Key or DOWN Key to display Fn021.
MODE/SET
DATA/
Press the DATA/SHIFT Key for approximately one
second. The display shown at the left will appear.
MODE/SET
DATA/
Press the MODE/SET Key to reset the motor type
alarm. donE will flash on the display and the display
MODE/SET
DATA/
shown on the left will appear again.
Press the DATA/SHIFT Key for approximately one
second to return the display to Fn021.
MODE/SET
DATA/
Keys
Press the MODE/SET Key to enter Utility Function
Mode.
MODE/SET
DATA/
Press the UP Key or DOWN Key to display Fn030.
MODE/SET
DATA/
Press the DATA/SHIFT Key for approximately one sec-
ond. The display shown at the left will appear.
MODE/SET
DATA/
Continue pressing the UP Key until the display shown
on the left appears.
Note: If you make a mistake during key operations, no_oP will
MODE/SET
DATA/
flash on the display for approximately one second.
Press the MODE/SET Key. The panel display will go
blank and then will change to the same initial status
display as when the power supply is turned ON.
MODE/SET
DATA/
Keys
Press the MODE/SET Key to enter Utility Function
Mode.
MODE/SET
DATA/
13.4.24 Resetting Motor Type Alarms (Fn021)
Operation
Operation
Operation
Continued on next page.
13
13-29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgd7s-****00a series

Table of Contents