6.6.2
CLR (Position Deviation Clear) Signal Function and Set-
tings
The CLR (Position Deviation Clear) signal is used to clear the deviation counter in the SERVO-
PACK.
As long as the CLR signal is ON, the deviation counter will be 0, so a position loop will not be
formed.
Deviation counter
The deviation counter counts the deviation between the reference input pulses and the feedback
pulses from the encoder (i.e., the accumulated pulses).
Term
CLR (Position Deviation Clear) Signal
Type
CLR
Input
/CLR
Setting the Form of the CLR (Position Deviation Clear) Signal
You set the CLR signal form to use to clear the deviation counter in Pn200 = n.X (Clear
Signal Form).
Parameter
n.0
(default setting)

n.
Pn200

n.

n.
The pulse width of the CLR signal must meet the following condition.
Information
• If Pn200 = n.X is set to 0 or 2, the width of the CLR signal must be at least 250 μs to
• If Pn200 = n.X is set to 1 or 3, the width of the CLR signal must be at least 20 μs to
Setting the Clear Operation (Pn200 = n.X)
This parameter determines when the position error should be set to zero according to the con-
dition of the SERVOPACK. Set Pn200 = n.X (Clear Operation).
Parameter

n.
0
(default setting)
Pn200

n.
1

n.
2
Signal
Connector Pin No.
CN1-15
CN1-14
Reference Form
Clear position deviation
when the signal is at high
level.
Clear position deviation
1
on the rising edge of the
signal.
Clear position deviation
2
when the signal is at low
level.
Clear position deviation
3
on the falling edge of the
signal.
reset the deviation counter.
reset the deviation counter.
Clear position deviation at a base block (at
servo OFF or when alarm occurs).
Do not clear position deviation. The position
deviation is cleared only with CLR (Clear Posi-
tion Deviation) signal.
Clear position deviation when an alarm occurs.

6.6.2 CLR (Position Deviation Clear) Signal Function and Settings

Position deviation clear input
Clear Timing
ON
CLR
Cleared.
(CN1-15)
ON
CLR
(CN1-15)
Cleared here ju t once.
CLR
OFF
(CN1-15)
Cleared.
CLR
OFF
(CN1-15)
Cleared here ju t once.
Meaning
6.6 Position Control
Name
When
Classification
Enabled
After restart
Setup
When Enabled
Classification
After restart
Setup