5.13 Holding Brake
5.13.4 Output Timing of /BK (Brake) Signal When the Servomotor Is Operating
• When the Time Set In Pn508 Elapses after the Power Supply to the Motor Is Stopped
/ -ON input, alarm,
or power OFF
Motor peed
Motor power tatu
/BK ignal
Important
5-40
ON
OFF
Rotary ervomotor: Pn507
Linear ervomotor: Pn58
Power
upplied.
Power not upplied.
ON (Brake relea ed.)
Pn508
The Servomotor will be limited to its maximum speed even if the brake reference output speed
level (Rotary Servomotor: Pn507, Linear Servomotor: Pn583) is higher than the maximum speed.
Motor topped with dynamic
brake or by coa ting
(Pn001 = n.
OFF (Brake
applied.)
X)