6.13.7 Alarm Output from the Output Ports for the Position Data from the Absolute Linear Encoder
Symbol
P
'
Lower 20 bits of the position data of the origin
S
P
Current position in machine coordinate system
M
R
1048576 (=220)
Note: The above formulas also apply in reverse movement mode (Pn000 = n.1).
If you are using a Linear Servomotor, you do not need to reset the absolute linear encoder to
Information
define the origin. (Some absolute linear encoders also allow you to set any position as the origin.)
6.13.7
Alarm Output from the Output Ports for the Position
Data from the Absolute Linear Encoder
Any alarm detected by the SERVOPACK is transmitted as the upper 16-bit data (with sign) to the host
controller with the PAO (Encoder Divided Pulse Output) signal when the SEN (Absolute Data Request)
turns OFF.
ALM ignal
Motor power
tatu
Main circuit
power upply
Control power
upply
EN ignal
PAO ignal
The data format of the alarm information is shown below.
A
L
M
0 to 9
Upper two digit
0 to 9
of alarm code
.
CR
Meaning
ervo ON
ervo OFF (Power not upplied.)
(Power upplied.)
ON
OFF
ON
ON
OFF
Encoder Divided Pulse
Output (PAO and PBO)
Signals
Encoder Output Resolu-
tion (Pn281)
Alarm information
6.13 Absolute Linear Encoders
Continued from previous page.
Setting or Unit
Absolute Encoder
Position Output (PSO)
Signal
Encoder pulses
6