The allocations are given in the following table.
Display Digit
Number
1
2
3
4
5
6
7
8
The configuration of the input circuits is shown below.
Information
OFF: Open
ON: Closed
Example:
 Display Examples
Display examples for input signals are shown below.
• When the /S-ON (Servo ON) Signal Is ON
8
7 6 5 4
• When the /S-ON (Servo ON) Signal Is OFF
8
7 6 5 4
• When the P-OT (Forward Drive Prohibit) Signal Is Active
8
7 6 5 4
13.3.3

Output Signal Monitor (Un006)

You can use Un006 to display the status of allocated signals on the LED segments of the Panel
Operator.
 Interpreting the Display
LED Segments
8
7
6
5
4
• If the output signal that corresponds to the display digit number is OFF, the top LED segment
will be lit.
Input Pin Number
CN1-40
/SI0 (/S-ON)
CN1-41
/SI3 (/P-CON)
CN1-42
/SI1 (P-OT)
CN1-43
/SI2 (N-OT)
CN1-44
/SI4 (/ALM-RST)
CN1-45
/SI5 (/P-CL)
CN1-46
/SI6 (/N-CL)
CN1-4
SEN
ERVOPACK
OFF (open)
The bottom egment of digit 1 i lit.
2 1
The top egment of digit 1 i lit.
2 1
The top egment of digit
2 1
Top: OFF
Bottom: ON
2 1
Di play digit number
13.3 Monitor Display (Un) Operations on the Panel Operator
13.3.3 Output Signal Monitor (Un006)
Signal Name (Default Setting)
i lit.
13
13-9