Retrieve Japan Sine Output Parameters

This command returns the settings for the specified Japan Sine Output module or
port.
Syntax
RTRV-PRMTR-OUTSINE:[tid]:[aid]:ctag;
Parameter
[aid]
Response Format
When the aid specifies a port, the response is:
^^^"aid:bypass,frequency,pstate,squelch"<cr lf>
where:
= port access identifier
aid
= allow Clock C selection: [ON | OFF]
bypass
frequency
= port state [ON | OFF]
pstate
= [0 | 1 – 16] (where 0 = disabled). If the reference clock PQL exceeds
squelch
this threshold value, then the output is turned off.
When the aid specifies a module, the response is:
^^^"aid: bypass,frequency"<cr lf>
^^^"aid:pstate1,pstate2,pstate3,...pstate20"<cr lf>
^^^"aid:squelch1,squelch2,squelch3,...squelch20"<cr lf>
Line 1 contains:
aid = module access identifier
= allow Clock C selection [ON | OFF]
bypass
frequency
Line 2 contains:
aid = module access identifier
= port state [0 | 1] where 0 = Off and 1 = On, and # = port number [1 –
pstate#
20]
12713020-003-2 Revision F.01 – January 2007
Value
Retrieves the parameters from all Japan Sine Output
ALL
modules in the shelf.
Retrieves parameters from the specified Japan Sine
SxAy[-z]
Output module [or port].
= output in MHz [1.544 | 6.312]
= output in MHz [1.544 | 6.312]
Chapter 2 TL1 Reference
Retrieve Japan Sine Output Parameters
Description