Table 6-20. DS1 LRM Alarm and Event Messages
Alarm/
Typical Alarm/Event/Trap
Event/
Response
Trap ID
000
LOS, Fault
001
AIS, Fault
002
LOF, Fault
003
BPV, Fault
004
SLIP, Fault
005
LOS, Side2, Fault
010
REF PLL, Fault
011
CTA Fuse, Fault
012
CTA, Fault
129
Install, DS1 LRM Module
130
Remove, DS1 LRM Module
131
Enable, DS1 LRM Module,
COML
132
Disable, DS1 LRM Module,
COML
133
Restart, in 5 seconds, COML
145
CTA, Not Installed
146
Signal Path, CTA
Disengaged, LOS
193
Port Cntl, Port[2-3], Disable,
COML
196
SlipCount, Port[2-3], 4, COML
197
BPV Err, Port[2-3], Clr,
COML
198
Fault Strategy, Port[2-3],
Squelch, COML
199
Circuit ID, Set
251
Err Delay, (0), 10 sec, COML
252
Alm Level, (1), Min, COML
254
Setup, Factory, COML
318 SSU-2000 Technical Reference
Corrective Action
Verify signal is connected. To extinguish alarm, disable port.
Verify input signal is good. Port can be disabled.
Loss of frame
Verify port ZS is on. Verify signal is good
Accumulated slip value exceeded threshold setting
Verify signal on side 2 is connected. Can be cleared by disabling
port.
Verify clock reference source is good. Reference PLL is unlocked
Verify CT/A fuse is good
CT/A present/not present, Mismatch Dual/Quad.
Module Installed.
Module Removed.
Module Enabled.
Module Disabled.
User request for a module to reboot.
Assembly not installed.
Signal is through either the Retimer module or Cut-Through
Assembly.
A user disabled the port control on ports 2 and 3.
A user set the slip count on ports 2 and 3 set to 4.
A user cleared the accumulated BPV error count.
A user changed the Reference Fault Strategy for CTA Action.
A user changed the Port Circuit ID.
A user changed the alarm delay time.
A user changed the alarm level.
A user set the unit to factory defaults.
Description/