Set Alarm Level Parameters - Symmetricom SSU-2000 Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Chapter 2 TL1 Reference

Set Alarm Level Parameters

Set Alarm Level Parameters
This command assigns an alarm level to the alarm number specified.
Syntax
SET-PRMTR-ALARM:[tid]:aid:ctag::almnum,level[,errcnt],[clrcnt];
Parameter
aid
almnum
level
errcnt
clrcnt
Related Commands
Retrieve All
134 SSU-2000 Technical Reference
Format
Sets the alarm level parameters for the specfied module.
SxAy
Specifies the alarm number to be modified. See
6, Alarms and Events
Sets the alarm level of the specified alarm number.
IGN
RPT
MIN
MAJ
CRT
Specifies the start delay time, which is the number of
seconds that the alarm must be present before the alarm
message is issued.
Specifies the clear delay time, which is the number of
error-free seconds after the alarm condition is cleared
before the alarm indication is cleared.
Alarms, on page 42
Description
for a list of alarm numbers.
12713020-003-2 Revision F.01 – January 2007